Setup Mode
The Setup Editor
7-65
Duplicate Zone (DupZn)
This adds a new zone with the same parameters as the current zone.
Import Zone (ImpZn)
You can import, or “bring in,” any zone from any setup in memory. Press ImpZn, and use any 
data entry method to choose a setup to import from. Then use the Chan/Zone buttons to select 
one of that setup’s zones. Now press Import, and the zone you selected will be added to the 
current setup.
Note: If you are using all 16 zones in a setup and you try to add, duplicate, or import a zone, a 
“No More Zones” message appears. You must delete an existing zone before you can add, 
duplicate, or import any new ones.
Delete Zone (DelZn)
This deletes the current zone from the setup. Use DelZn to free up zones so you can add or 
import new ones.
Set Controls KB3 (KB3CTL)
Press this button if you want to assign the setup’s knobs and switches to control organ functions 
(if you have a KB3 organ program in the current setup.) Organ functions for KB3 programs are 
labeled on the front panel under the switches and knobs. When you press the KB3CTL soft 
button, you will be prompted to continue by pressing OK, or to cancel and return to the 
previous screen by pressing CANCEL. Caution: This will clear any existing knob or switch 
assignments.
For setups with KB3 and V.A.S.T. programs, you can program a switch to toggle back and forth 
between having the knobs and assignable switches function as they would with KB3 programs, 
or having the switches function as zone mute buttons. To do this, in the Setup editor, first use the 
KB3CTL soft button as explained above. Next, go to the Controllers page (by pressing the 
CTRLS soft button.) On the Controllers page, select the Controllers field, hold the Enter button 
on the alphanumeric pad and press the ArpLatch button (above the Mod Wheel) to choose Arp. 
latch sw for the controller field (alternatively the Arp Enable button (Arp. switch) can be used.) 
On the Controllers page for Arp. latch sw, use the cursor buttons to select the DestType field and 
set it to Ctrl. Next, select the OnControl field and set it to KB3Mutes by entering 169 and 
pressing the Enter button on the alphanumeric pad. Do the same for the OffControl field. Leave 
the other fields at their defaults: Type=Toggled, OnValue=127, OffValue=0. Make these 
Controller page settings for all zones in the setup. Now when you press and light the ArpLatch 
button the assignable switches work as zone mute buttons (see below.) When you press and 
unlight the ArpLatch button the assignable switches work as KB3 controls. Make sure to save 
your setup to keep these changes. Caution: This will clear any existing knob or switch 
assignments.
Set Controls Zone Mutes (MUTES)
Press this button if you want to assign the setup’s switches to control zone muting. Switches 1 
through 10 will mute zones 1 through 10 respectively. A switch with a lit LED means it 
respective zone is active, a switch with an unlit LED means it respective zone is muted. When 
you press the MUTES soft button, you will be prompted to continue by pressing OK, or to cancel 
and return to the previous screen by pressing CANCEL. Caution: This will clear any existing 
switch assignments.