Multi Edit Mode
Controllers Page
5-9
Ctl
Use the Ctl parameter to select a controller. When the Ctl parameter is selected, you can
select a controller by using the ALPHA WHEEL, or by holding the ENTER button and
moving the MODULATION WHEEL or one the KNOBS.
Value
Use the Value parameter to set a value (0-127) for the selected controller.
When the Value parameter is selected, you can set a value by using the ALPHA WHEEL, or
by using the keypad function of the CATEGORY buttons to type a value (0-127) followed
by pressing the ENTER button.
When the Value parameter is selected, you can also set a value by holding the ENTER
button and moving the MODULATION WHEEL or one the KNOBS.
State
Use the State parameter to enable or disable the selected controller in the selected Zone.
When a Zones State parameter is set to Yes, the selected controller is active.
When a Zones State parameter is set to No, the Program in that Zone will not be controlled
by the selected controller. e Program in that Zone will use the controller setting that the
Program was saved with in Program Mode.
Scale
Use the Scale parameter to scale the value of the selected controller for each Zone. e Scale
parameter multiplies the current value of the controller by the selected Scale amount (-300%
through 300%). Press the MULTI Mode button to quickly apply the selected value.
e Scale parameter eectively allows you to apply dierent values to each Zone, while
maintaining a single value for each controller. For example, with the Ctl parameter set to
Reverb, you could set the Zone 1 Scale parameter to 100%, and the Zone 2 Scale parameter
to 50%. With the REVERB knob set to 127, Zone 1 would have a Reverb value of 127, and
Zone 2 would have a Reverb value of 63. With the REVERB knob set to 64, Zone 1 would
have a Reverb value of 64, and Zone 2 would have a Reverb value of 32.