Q: Shutter doesn’topen, and its plate blocks the output
(inILDA operation mode).
A: Inthe ILDA operation mode, the shutter isalso controlled
with the “shutter” signal from anexternal controller. Check
the ILDA cable, mainly if pin #13 is connecting properly.
Werecommend using only original ILDA cables.
Q: Shutter doesn’topen, and its plate blocks the output.
A: If the shutter doesn’t open in any operation mode,
please contact your distributor or technical assistance
ofKvant Lasers, s.r.o.
Q: The projector ispowered ON, ready for emission, but
the FB4 display is inactive. And itdoesn’t turn on after
pushing or turning the encoder knob next to the FB4
display.
A: Perform apower cycle procedure with the mains power
switch orunplugging the mains power cable for 5seconds.
After the power cycle, the display should start working
correctly.
Q: One ofthe RGB colours doesn’twork.
A: Check colour settings inthe FB4 menu and make
sure that all R, Gand Bcolours are set at100%. Ifthe
projector doesn’thave abuilt-inFB4 controller, check the
brightness potentiometers atthe rear panel - all three
should beset tothe maximum level.
Ifall the above isasdescribed and the problem persists,
turn o the mains power switch (ordisconnect the mains
power cord) for 10minutes.
All PSUs should fully discharge and cool down.
After 10 minutes, power up the projector. If overloaded
PSUs caused the malfunction, itshould now work correctly
again.
Q: One ofthe RGB colours doesn’twork (ILDA operation
mode only).
A: Check connection onboth ends ofthe ILDA cable and
inspect the ILDA male connector’spins.
Q: Scanning isunstable or distorted on both the Xand
Yaxes (ILDA operation mode only).
A: Distortion of the scanned eects can occur when
the projector and the PC (controller) are not connected
tothe same mains power phase due todierent PEwire
potentials (Earth).
Always connect the PC/controller and the laser projector
tothe same mains power socket when operating inILDA
mode.
Q: The projection size isreduced toabout 50% onone
orboth ofthe Xand Yaxes.
A: Check Master Settings inthe FB4 menu and ensure both
axes size are set to100% size. Ifthe projector doesn’thave
FB4 controller build-in, ensure both Xand Ypotentiometers
located onthe rear panel are set tothe maximum level.
Ifall the above isasdescribed and the problem persists,
check ILDA cable connectors onboth sides and the ILDA
input connector onthe projector. One or more of#1, #2,
#14, #15pins may bebent ordamaged.
Q: One colour ofthe projected eect isshifted out from
others - misaligned.
A: Itisnecessary toreset the output directions (alignment)
of individual colours (laser beams) inside the projector.
There are several ways how tojoin them together, but only
one is correct. The correct one ensures perfectly joined
beams atboth short and long-distance projections. Please
check the User manual (chapter Beam alignment) for beam
alignment instructions.
Q: Projector #2doesn’twork when connected tothe ILDA
output ofprojector #1.
A: Try toreplace the ILDA cable with anew one between
projectors and check the ILDA input connector onprojector
#2for any damage. Ifthis does not solve the issue, exchange
the projectors one for another and see if that works.
Ifboth work fine, then projector #1has faulty ILDA output.
If none of them is working, then projector #2 has faulty
ILDA input. Please contact your distributor or technical
assistance ofKvant Lasers, s.r.o. for further help.
Q: Projection is blurred or foggy. Static beams (points)
have ahalo around them. How tofix this?
A: This isusually anoptical problem such asscratches, dust
and dirt onthe components onthe beams’ path from their
source tothe output aperture; oronthe aperture glass itself.
Use aclean fine-cotton cloth soaked with isopropyl alcohol
toclean the surface ofthe output window. Clean itcarefully
soyou won’tscratch the surface with dirt particles already
stacked tothe cloth.
Remember that the output window’s anti-reflex surface
can be easily scratched and permanently damaged
byanincorrect cleaning process.