How to restore default settings
This procedure will delete all User Codes associated with the lock, and the default Mastercode (0-0-0-0) and User Code (1-2-3-4) will be
restored.
1. Make sure the door is open and unlocked. Press and hold the Reset button for 5 seconds, until you hear 3 long beeps.
2. Enter the default Mastercode (O-O-O-0).
3.
Press the lock button. Y
ou will hear one beep.
4. Press 0.
5.
Press the lock button. The latch bolt will extend and retr
act to learn the orientation of the door. If successful, the keypad will flash green
and you will hear 2 beeps. If unsuccessful, the keypad will flash red and you will hear 3 beeps (make sure the door is open and unlocked
and that you are using a fresh set of batteries).
6. Test the lock: With the door open and unlocked, Press the lock button. Make sure it locks the door.
7. Test the default User Code: Enter the default User Code (1-2-3-4), then press . Make sure it unlocks the door
.
The default Mastercode is 0-0-0-0. It is recommended that you change it to a code of your own. The lock is pre-programmed with a default
User Code of 1-2-3-4. It is recommended that you delete this code.
On my Powerbolt 2, the keypad flashes red 3 times with 3 beeps.
There are four reasons for this to occur:
1. Door jammed while attempting to lock. Manually re-lock door
. If needed, reposition strike.
2. Door handing code has not been entered. Enter door handing code.
3. No User Code progr
ammed, or User Codes are disabled. Program at least one User Code, or re-enable User Codes.
4. Unsuccessful programming. Attempt programming procedure again.
5. Incorrect User Code entered. Re-enter User Code
On my Powerbolt 2, the keypad flashes red 5 times with 5 beeps.
5 incorrect User Codes entered within one minute. R
e-enter User Code after 45-second k
eypad lockout.
On my Powerbolt 2, the keypad flashes red 10 times with 10 beeps.
Low battery. Replace batteries
On my Powerbolt 2, the lock cannot be locked or unlocked by the keypad.
Make sure the lock is programmed with at least one User Code and that the User Codes are not disabled. If needed, restore the lock’s
default settings.
On my Powerbolt 2, The keypad doesn’t respond when touched (no lights are
visible and no beeping is heard).
Make sure the cables are properly connected, and make sure the batteries are new and installed correctly.
On my Powerbolt 2, The door can be locked with the Lock button, but the User
Code will not unlock the door.
Make sure the User Code is correct and that the Lock button is pushed after entering the User Code. If the door still won’t unlock, use a key
to unlock the door. Call technical support for further troubleshooting.
Can I get a replacement for the key pad buttons or screws on my Powerbolt 2?
Kwikset covers their locks under a Limited Lifetime Warranty.
How to mute/unmute lock on my Powerbolt 2?
How to mute/unmute lock
If the lock is muted, you will not hear beeping during programming, normal operation, low battery indicators, or system alerts.
1. Make sure the lock is unlocked and the door is open.
2. Enter your Mastercode.
3. Press the lock button. You will hear one beep.
4. Press 1 - 5.
5.
Press the lock button. Y
ou will hear two beeps if successful. If you hear three beeps, it was unsuccessful. Repeat from step 1 slowly.
How to restore default settings on my Powerbolt 2? Perform a factory reset

Other manuals for Kwikset Signature Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kwikset Signature Series and is the answer not in the manual?

Kwikset Signature Series Specifications

General IconGeneral
KeywayKW1
MaterialMetal
FinishSatin Nickel, Venetian Bronze, Polished Brass
Security GradeANSI Grade 2
Re-key TechnologySmartKey
CompatibilityStandard doors
Strike PlateReinforced
Door Thickness1-3/8" to 1-3/4"
BacksetAdjustable 2-3/8" or 2-3/4"
HandingReversible
WarrantyLimited Lifetime