1-5-76
61. Confirm the conductivity between the
ground spring M and the machine right
side's edge of the shaft.
(Electric resistance: 10 or less)
62. Affix two double-sided tapes bundled in
the ISU for service while aligning their
edges to the engravings on the scanner
frame.
63. Affix the ISU side's folding part of the
FFC wire to the double-sided tapes.
64. Refit the ISU cover and the operation
cover in the reverse procedures of
removal.
Figure 1-5-123
(Scanner unit inside)
Edge of the shaft at
the machine right side
Ground spring M
FFC wire
Dabble-sideed
tape
Engravings

Table of Contents