EasyManua.ls Logo

Kyocera ECOSYS M6026cidn

Kyocera ECOSYS M6026cidn
375 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2PX/2PY
2-3-11
YC34 1 TNSENM I Analog TS-M detection voltage
Connected to
drum relay
PWB
2 ERASECDR O 0/24 V DC CL-C: On/Off
3 TNSENK I Analog TS-K detection voltage
4 ERASEMDR O 0/24 V DC CL-M: On/Off
5 DLPTHERM I Analog DEVTH detection voltage
6 ERASEKDR O 0/24 V DC CL-K: On/Off
7 +3.3V2 O 3.3 V DC 3.3 V DC power to DRRPWB
8 EECLK O 0/3.3 V DC (pulse) EEPROM clock signal
9 GND - - Ground
10 EEDATA I/O 0/3.3 V DC (pulse) EEPROM data signal
11 TNSENY I Analog TS-Y detection voltage
12 ERASEYDR O 0/24 V DC CL-Y: On/Off
13 TNSENC I Analog TS-C detection voltage
YC35 1 DLPDIRN I 0/3.3 V DC DEVRSW: On/Off
Connected to
developing
release
switch and
developing
release
motor
2 GND - - Ground
3 DLPCMOTA O 24/0 V DC DEVRM: Forward/Stop (Reverse)
4 DLPCMOTB O 24/0 V DC DEVRM: Reverse/Stop (Forward)
YC36 1 LSUMOTA O 24/0 V DC LSUCM: Forward/Stop (Reverse)
Connected to
LSU clean-
ing motor
2 LSUMOTB O 24/0 V DC LSUCM: Reverse/Stop (Forward)
YC37 1 STDUBN O 0/24 V DC (pulse) DUM drive control signal
Connected to
duplex motor
2 STDUAN O 0/24 V DC (pulse) DUM drive control signal
3 STDUB O 0/24 V DC (pulse) DUM drive control signal
4 STDUA O 0/24 V DC (pulse) DUM drive control signal
YC38 1 PREMOTDRN O 0/24 V DC FPRM: On/Off
Connected to
fuser pres-
sure release
motor
2 GND - - Ground
YC40 1 +24V1 O 24 V DC 24 V DC power to FUFM
Connected to
fuser fan
motor
2 FUFANDRN O 0/12/24 V DC FUFM: Full speed/Half speed/Off
Connector Pin Signal I/O Voltage Description