2PX/2PY
2-3-25
Connector Pin Signal I/O Voltage Description
YC1 1 MOTA1 I 0/24 V DC (pulse) DPPFM drive control signal
Connected to
main PWB
2 MOTB1 I 0/24 V DC (pulse) DPPFM drive control signal
3 MOTA2 I 0/24 V DC (pulse) DPPFM drive control signal
4 MOTB2 I 0/24 V DC (pulse) DPPFM drive control signal
5 +24V2 I 24 V DC 24 V DC power from MPWB
6 GND - - Ground
YC2 1 +3.3V2 O 3.3 V DC 3.3 V DC power to DPOCS
Connected to
DP open/
close sen-
sor, DP origi-
nal sensor
and DP tim-
ing sensor
2 GND - - Ground
3 OPSWN I 0/3.3 V DC DPOCS: On/Off
4 +3.3V2 O 3.3 V DC 3.3 V DC power to DPOS
5 GND - - Ground
6 ORGSWN I 0/3.3 V DC DPOS: On/Off
7 +3.3V2 O 3.3 V DC 3.3 V DC power to DPTS
8 GND - - Ground
9 TIMSWN I 0/3.3 V DC DPTS: On/Off
YC3 1 DPMOT1A O 0/24 V DC (pulse) DPPFM drive control signal
Connected to
DP paper
feed motor
2 DPMOT2A O 0/24 V DC (pulse) DPPFM drive control signal
3 DPMOT1B O 0/24 V DC (pulse) DPPFM drive control signal
4 DPMOT2B O 0/24 V DC (pulse) DPPFM drive control signal
YC4 1 +24V2 O 24 V DC 24 V DC power to DPPRSOL
Connected to
DP pressure
solenoid
2 PRESOLN O 0/24 V DC DPPRSOL: On (Press)/Off
3 RELSOLN O 0/24 V DC DPPRSOL: On (Release)/Off
YC5 1 +24V2 O 24 V DC 24 V DC power to DPSBSOL
Connected to
DP switch-
back sole-
noid
2 REVSOL O 0/24 V DC DPSBSOL: On/Off
YC6 1 +24V2 O 24 V DC 24 V DC power to DPPFCL
Connected to
DP paper
feed clutch
2 FEEDCL O 0/24 V DC DPPFCL: On/Off

Table of Contents