2F8/2F9/2GA-2
1-5-29
5. Remove the eight screws and three ground-
ing terminals.
Figure 1-5-39
6. Remove the AC inlet.
7. Remove the one connector.
8. Remove the PWB connector between con-
nect-L PWB and then remove the power
source unit.
9. Remove the power source unit.
10. Check or replace the power source unit and
refit all the removed parts.
Figure 1-5-40
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Grounding
terminal
Grounding
terminal
Grounding
terminal
PWB connector
Connect-L PWB
Connector
Power source unit