8. Battery & Fuse Replacement
8-1 Battery Replacement
Disconnect the test probe from the instrument.
Open the battery compartment cover by unscrewing the metal captive
screw to reveal battery compartment. Always replace all six batteries
with new ones at the same time.
Battery type: 6 x 1.5V battery type SUM-3, R6, AA or equivalent
8-2 Fuse Replacement
Disconnect the test probe from the instrument.
Open the battery compartment cover by unscrewing the metal captive
screw to reveal battery compartment and replace the fuse.
Fuse type: F500mA/600V fast acting ceramic fuse φ6.35 x 32mm
Install batteries in correct polarity as marked inside the case.
#
DANGER
Never open the battery compartment cover while making measurement.
   To avoid possible electrical shock, disconnect the test probe before
opening the cover for battery and fuse replacement.
Replacement fuse must have the following rating.
  Fast acting type, F500mA/600V, φ6.35×32mm
Fig.8How to replace batteries and fuse
SPARE FUSE
SCREW
FUSE
BATTERY
www.GlobalTestSupply.com