―3―
2.Features
KEW3021/3022/3023arefour-rangedigitalinsulationresistance
testersfortestinglow-voltageinstallationbelow600V.Resistance
measurementwithaudibleContinuitycheckfunctionisalsoavailable.
¡
Designedtofollowingsafetystandards:
IEC61010-1(CAT.III600VPollutiondegree2)
IEC61010-031(Requirementsforhand-heldprobes)
¡
Smallandlightweight.
¡
Auto-dischargefunction
Wheninsulationresistancelikeacapacitiveloadismeasured,electric
charges storedincapacitivecircuits are automatically discharged
aftermeasuring. Dischargecan bechecked withthe LED&
markonLCD.
¡
Tworesistance ranges: 40Ω and400Ω (2-range auto)arealso
available.Buzzersoundswhenameasuredcurrentexceeds
200mA.
¡
Thisinstrumenthas0Ω ADJ.functiontonulltheresistanceoftest
leadorfuseatresistancemeasurement.
¡
Measuredvalueisheldforabout5sec.afterinsulation/resistance
measurementoftheTestbuttonisreleased.
¡
Backlightfunctiontofacilitateworkatnightordimlylitlocations.
¡
Bar-graphtoindicatemeasuredresults
¡
Max.99datacanbesavedtotheinternalmemoryattheinsulation
resistancerange.
¡
Visible andaudiblewarning( or isindicated and buzzer
sounds)whenthemeasuredinsulationresistanceexceedsthepre-
setvalue.
¡
Livecircuitwarningindication,LEDandbuzzer.
¡
TheSafetykeymustbekeptpresseddowntoselect500Vor1000V
range. Otherwise,neither500Vor1000Vrangecanbeselected.
¡
Auto-powerofffunction
Topreventtheinstrumentbeing leftpowered onandconserve
batterypower, theinstrumentautomatically turnsoff approx. 15
min.afterthelastswitchoperation.
¡
The markflickerswhenthebatteryvoltagedropstothelower
limit.
¡
Testleads with remote controlswitch(voltage won't beoutputted
whenthetestleadisnotconnected.)
¡
Robusthousingcase
¡
Neckstrapforbothhand'soperation
¡
User-changeabletestprod