COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Rev. 02 Page 145
July 21/17
Testing & Fault Isolation
23–7030
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Table 104 Main Processor Troubleshooting Chart (Continued)
Item
ID
Function Type Failure
Mode
Local Effect Next Effect End Effect
B019
Analog
Area
MIC
Audio
LO
Audio I/P LO Analog Area
MIC I/P LO is
open
Inputs Channel
4 and the Area
Microphone
Channel LO
both get pro-
cessed at the
same time
The system is
unable to con-
vert the Area
Microphone in-
terface signal
to differential
format in order
to be compat-
ible with Chan-
nel 4 Audio Mi-
crophone LO
input
Loss of Channel 4 Audio Mi-
crophone LO
Audio I/P LO Analog Area
MIC I/P LO is
shorted
Inputs Channel
4 and the Area
Microphone
Channel LO do
not get pro-
cessed at all
No Effect No Effect
E020
CAM
and
Pre
Amp
Power
Audio I/P Power The CAM
and Pre Amp
Power are
open
The power is
note available
to the Cockpit
Area Micro-
phone or the
Preamplifier
Power
Loss of Cockpit
Area Micro-
phone &
Preamplifier
Power
Loss of Cockpit Area Micro-
phone & Preamplifier Power
Audio I/P Power The CAM
and Pre Amp
Power are
shorted
The output
voltage is not
disrupted and
the system
/FPGA/DAP
softeware is
not alerted
The system
softeware is
unable to dis-
rupt this output
via control pin
from the FPGA
Loss of Cockpit Area Micro-
phone & Preamplifier Power
F021
Analog
Audio
Monit-
or O/P
Ch HI
Audio O/P HI The Analog
Audio Monit-
or O/P Ch HI
is open
The high out-
put is not
scaled up by
the output
stage and
does not pass
through the
output trans-
former
The Analog Au-
dio Monitor
Output Chan-
nel HI does not
function
Loss of the Analog Audio Mon-
itor Output Channel HI
Audio O/P HI The Analog
Audio Monit-
or O/P Ch HI
is shorted
The high out-
put is not
scaled up by
the output
stage and
does not pass
through the
output trans-
former
The Analog Au-
dio Monitor
Output Chan-
nel HI does not
function
Loss of the Analog Audio Mon-
itor Output Channel HI
The document reference is online, please check the correspondence between the online documentation and the printed version.

Table of Contents