COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Assembly
23–70–30
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Rev. 02 Page 708
July 21/17
(7) Torque the RIPS Module retaining screw from 22 to 30 in-lbs.
(8) Perform a Return to Service Test on the recorder in accordance with Section
100 of this CMM.
NOTE: The RIPS Module should provide sufficient holdup time after the
first application of power for at least 15 minutes. Once charged,
the battery should remain sufficiently charged for at least 1 year
without application of power to the recorder (when operated
within this requirement, no monitoring is required.) The RIPS
battery is an ondemand maintenance item, and required main-
tenance will be indicated over the recorder’s ARINC 429 OMS.
The document reference is online, please check the correspondence between the online documentation and the printed version.