14
SERVICING WARNING WORK SAFELY
Where necessary disconnect from electricity and gas before starting.
Check range is safe when you have finished.
A left rear roller, B right rear roller, C center roller
Fit the Allen key tool to the center roller lowering
mechanism (C in the fi g.).
Lower the front roller by turning the Allen key
clockwise until the front feet are just clear of the
fl oor.
Open both oven doors and with your hands griping under the control panel slide, the range forward to disengage
from the anti-tip bracket. Do not pull the range by the handrail.
Reverse procedure to reinstall. If gas line has been disconnected, check for gas leaks after re-connection.
NOTE: A qualifi ed person should disconnect and reconnect the gas supply.
The service engineer MUST follow installation instructions provided with the gas appliance connector and the
warning label attached to the connector.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
When using test pressures greater than ½ psig (3.5kPa) to pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of ½ psig
(3.5kPa) or less to test the gas supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
If the range is removed for any reason, make sure the anti-tip device is re-engaged properly when the range is
replaced. Failure to take this precaution could result in tipping of the range and cause injury.
Replace the storage drawer
To replace the drawer in the range, pull the side rails fully out.
Carefully move the drawer back between the rails
and rest it on the side rails.
At each side hold the front of the drawer and pull the
side rail forward so that the clips click into position
holding the drawer to the side rails.