FAULT CODES
Too many labels missing on web
Labeler not webbed properly
Label sensor not adjusted properly
Check label stock.
Check for proper webbing.
Check Label Sensor setting.
Head up limit switch on tamp did not
trigger
Check for proper adjustment of head
up limit switch.
Check air to system.
Check programming of Tamp switch.
Head up limit switch failed to switch
during the tamp cycle
Tamp duration too small.
Faulty limit switch.
Check air to system.
Check programming of Tamp switch.
Switch on Round Module failed to
change state during cycle.
Check switch function.
Inspect Cable for damage.
Adjust Carriage Position.
End of Print Signal was not received
with "Printer" setting enabled
Turn off Printer setting (if external
printer is not being used).
Check Printer Settings.
Inspect / Replace Interface Cable.