FAULT MESSAGES
Data lost in serial EEPROM
Consult factory or service provider
Printer failed to print or
Control failed to receive a “End
Print Signal”
B. No Label Formats Loaded
C. Check Printer Interface Cable
D. Printer mode incorrect
Head up limit switch failed to
switch during the tamp cycle.
Cylinder did not move off of reed
switch.
A. Tamp Cylinder Is Not Up
B. No Air
C. Faulty Valve
D. Flow Control Miss Adjusted
E. Miss Adjusted Reed Switch
F. Faulty Reed Switch
G. Tamp duration too small
H. Check programming of Tamp switch
NOTE: Light on reed switch should be on when
cylinder is up
Head up limit switch failed to
switch during the tamp cycle.
Cylinder did not return up.
A. Tamp Cylinder Is Not Up
B. No Air
C. Faulty Valve
D. Flow Control Miss Adjusted
E. Miss Adjusted Reed Switch
F. Faulty Reed Switch
G. Tamp duration too small
H. Check programming of Tamp switch
NOTE: Light on reed switch should be on when
cylinder is up
Trigger signal was not received
before timer expired. This FAULT
will only occur if “Variable Data”
feature is “ON”.
B. Check product delay
Check printer for label stock
4-02