LM-3605 Dynamic Label Applicator
USERS MANUAL
Page 45 Made in the U.S.A.
© 2019 LABELMILL
12/01/2019 Model LM3605
DESCRIPTION OF I/O
LEGEND
24V OPT: 24V OPTO INPUT WITH INTERNAL 24V COMMON
OH: HIGH CURRENT OUTPUT Rated @ 500ma
All user inputs and outputs are “SINKING” type. Example in order for a status light to illuminate for “Run Status
Ok” the light should be wired between pins #2 & #4 on the “Light Bar/Aux.” Connector.
Status display legend.
INPUTS OUTPUTS
S
P
H
Y
A
F
V
T
SMART
TAMP
PRODUCT
SENSOR
HEAD UP
TAMP
SENSOR
AUX OUT
#1
AIR ASSIST
SOL
FLAG
SOL
VACUUM
SOL
TAMP
SOL
P0.0 PAPER END INPUT 0=ON
P0.1 RIBBON END INPUT 0=ON
P0.2 PRINER ERROR INPUT 0=ON
P0.3 RIBBON NEAR END INPUT 0=ON
P0.4 PRINT END INPUT 0=ON
P0.5 ON-LINE INPUT 0=ON
P0.6 REPRINT OUTPUT 0=ON
P0.7 PRINT OUTPUT 0=ON
P1.3 RED LIGHT ON (GREEN OFF) 1=ON
P1.4 YELLOW LIGHT ON 1=ON
P1.5 LOW LABEL INPUT 0=ON
P1.6 TAKEUP MOTOR OUT 0=ON
P1.7 AUX INPUT (DISABLE) 0=ON
P2.0 NOT APPLICABLE 0=ON
P2.1 NOT APPLICABLE 0=ON
P2.4 VACCUM SOL OUT 0=ON
P2.5 AIR ASSIST OUT 0=ON
P2.6 ROUND MODULE OUT 0=ON
P2.7 FLAG SOL OUT 0=ON
P3.4 TRIGGER INPUT 0=ON
P3.5 HEAD UP SWITCH INPUT 0=ON
P3.6 SMART TAMP INPUT 0=ON
P3.7 PRE-PRINT START INPUT 0=ON
The bit not listed above are used for serial clock data, RS232, and internal functions
3-17