CAUTION: Read the instructions
prior to using the equipment
INSTALLATION AND
MAINTENANCE MANUAL
NABOO
SAPIENS
AROMA NABOO
AROMA SAPIENS
Question and Answer IconNeed help?

Do you have a question about the Lainox SAPIENS SAGV201 and is the answer not in the manual?

Lainox SAPIENS SAGV201 Specifications

General IconGeneral
CategoryOven
ModelSAPIENS SAGV201
Capacity20 GN 1/1
TypeCombi Oven
Temperature range30°C - 300°C
Humidity range0% - 100%

Summary

2 TECHNICAL DATA

3 SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE

3.3 Flue Gas Extraction Requirements

Room needs flue gas extraction stack or system, check authorization for emissions.

3.5 Water Supply Requirements

Requires two water supplies, one cooled, one potentially softened for steam.

3.7 Gas Supply Plumbing

Gas plumbing must meet regulations; fast-acting shutoff valve required.

6 ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING

6.1 Appliance Attachment and Power Supply

Oven has Type Y attachment; installer provides cable. Connect via isolating switch.

6.3 Cable Feeding and Earth Wire

Feed cable from beneath clamp, earth wire must be longer for safety.

6.4 Equipotential Bonding

Connect oven to equipotential system with a 10 mm² conductor for safety.

6.5 Electrical Safety Guarantee

Electrical safety is guaranteed only with correct connection to an efficient earth system.

6.6 Damaged Supply Cord

If supply cord is damaged, replacement must be by manufacturer or qualified personnel.

7 POINTS TO REMEMBER WHEN MAKING THE ELECTRICAL CONNECTION

7.2 Neutral Wire Connection

Ensure neutral pin matches supply neutral wire; incorrect connection prevents burner operation.

8 WATER AND DRAIN CONNECTIONS

8.1 Water Pressure Requirements

Water pressure must be 200-500 kPa; use reduction valve if higher.

8.3 Water Specifications

Water hardness (6-9°fH), pH (>7.5), and chlorides (<30 ppm) are critical.

9 WASHING SYSTEMS

10 CALOUT (if present)

12 GAS CONNECTION PROCEDURES

12.1 GAS CONNECTION

Requirements for choosing gas pipe sections, connection types, and shutoff valves.

13 OPERATING AT THE RATED HEAT OUTPUT

13.1 Gas Type Conversion

Appliance is factory set for specific gas; conversion may require customer service.

13.2 Commissioning Dependencies

Commissioning depends on inlet pressure, calorific value, and primary air.

13.3 Inlet Pressure Requirements

Inlet pressure must be within specified limits; contact supplier if different.

13.5 Measuring Inlet Pressure

Procedure for measuring inlet pressure using a manometer on the gas adjustment valve.

Checking Nominal Heat Capacity

Procedures for checking burner fan speed and depth of screw 'A'.

14 COMMISSIONING AND TESTING

14.1 Post-Connection Checks

Verify appliance and installation, check for protective film, clear vents, connections, leaks, and drainage.

14.2 Oven Ignition Check

Light the oven as directed and check for smooth burner ignition.

14.3 Water Circuit Leak Check

Check silicone joints and sleeves of the water circuit for leaks.

14.6 Gas Consumption Measurement

Measure gas consumption and compare with technical data for operational certainty.

14.7 Test Report and Warranty Start

Complete test report, submit to client, and sign for acceptance to start warranty.

15 IMPORTANT INFORMATION FOR THE USER

15.3 Emergency Shut-off Procedure

Advise user to shut off utilities immediately in case of breakdown or faulty operation.

17 INSTALLATION DIAGRAMS