5: Commands and Levels
EDS1100/2100 Command Reference 134
no queue name
Removes the queue name.
no soj text
Removes the start-of-job string.
ppp <line>
Enters the serial line PPP level.
queue name <text>
Sets the name of the queue that this lpd line belongs to.
<text> = name for the queue.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI
session.
show statistics
Displays statistics and status information for this lpd line.
soj disable
Disables sending the start-of-job string after each print job.
soj enable
Enables sending the start-of-job string after each print job.
soj text binary <binary>
Sets the start-of-job text allowing for binary characters.
<binary> = string in binary format that will be sent to the printer at
the
beginning of each print job.
Within [] use binary decimal up to 255 or hex up to 0xFF.
soj text set <text>
Sets the start-of-job text.
<text> = ascii string that will be sent to the printer at the beginning
of
each print job.
terminal <line>
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be configured.
terminal network
Enters the configure-terminal level for the network.
test print <number of lines>
Prints lines of text directly to the lpd line.
<number of lines> = number of lines to print.
tunnel <line>
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be configured.
write
Stores the current configuration in permanent memory.
modbus (modbus) level commands
additional port <number>
Sets an additional TCP server port.
clrscrn
Clears the screen.
default response timeout
Restores the default Modbus Response Timeout.
exit
Exits to the config level.
kill connection <index>
Kills modbus connection selected by index from show connections.
no additional port
Removes the additional TCP server port.
response timeout <milliseconds>
Sets the Modbus Response Timeout in milliseconds.
rss
Enters the next lower level.
show
Displays the current configuration.
show connections
Displays connections.
show history
Displays the last 20 commands entered during the current CLI
session.
show statistics
Displays statistics.
tcp server state disable
Disables the Modbus TCP Server.
tcp server state enable
Enables the Modbus TCP Server.
write
Stores the current configuration in permanent memory.