EASE1000 User’s Manual
Chapter 2 General Description
2.4 Terms of Use
EASE1000 should be used in an environment which meets the following conditions.
Terms of use for EASE1000
USB VBUS output (5 V, 500 mA) on the host PC
Temperature: 5 to 40 °C
Relative humidity: 30 to 80% (no condensation)
Target LSI
Positive power supply (VTref) voltage
Target LSI operation voltage
1.6 to 5.5 V
For an operating environment for software running on the host PC, see the following documents.
- DTU8 User's Manual
- MWU16 Flash Multi Writer Host Program User's Manual
When using EASE1000 as an on-chip emulator or flash writer, the power supply output from EASE1000 to the target
LSI is as follows:
Output power supply of EASE1000
Power supply for target LSI
(3.3VOUT)
The power supply for the target LSI is output after debugging with target LSI by DTU8 debugger or when
MWU16 Flash Multi Writer Host Program is in a plug state.
FEXTEASE1000-02 4