EasyManua.ls Logo

LaserLine LC800 - User Manual

LaserLine LC800
68 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IT
UK
MANUALE INSTALLATORE
FITTING INSTRUCTIONS
FILE NAME: ISLC800.cdr
rev.02
Data: 14-04-2022
SISTEMA DI ALLARME MODULARE
DOTATO DI INTERFACCIA
CAN-BUS E LIN-BUS
PER L’ABBINAMENTO DEL SISTEMA
AI RADIOCOMANDI
ORIGINALI DEI VEICOLI
DOTATI DI BATTERIA A 12V
MODULAR ALARM SYSTEM WITH
CAN-BUS AND LIN-BUS INTERFACE
FOR ORIGINAL REMOTE CONTROLS;
CARS EQUIPPED
WITH A 12V BATTERY
LC800 / LC800B / LC801
allarme CanBus con chiave
di emergenza.
CanBus alarm with
emergency key.
LC800RF / LC801RF
allarme CanBus con chiave
di emergenza e sirena via radio.
CanBus alarm with
emergency key and
wireless siren.
Question and Answer IconNeed help?

Do you have a question about the LaserLine LC800 and is the answer not in the manual?

LaserLine LC800 Specifications

General IconGeneral
Number of Beams4
Power Source12-24V DC
Ingress ProtectionIP66
TypeLaser Beam Detector
Range800 meters
Detection Range800 meters
Laser Wavelength905 nm

Summary

GENERAL INSTALLATION NOTE

WARRANTY CONDITION

Details warranty terms, coverage, exclusions, and dispute resolution.

KIT DESCRIPTION

PRODUCT DIFFERENCES LC 800 SERIES

Compares features across different LC800 series models.

CONNECTION DIAGRAMS

LC800;LC800 B Internal Battery

Wiring diagram for LC800/LC800B models with internal battery.

CONNECTION DIAGRAM LC801

Self-Powered Siren Wiring

Wiring diagram for the self-powered LC801 model.

CONNECTION DIAGRAM LC800-RF;LC801-RF

Wireless Siren Wiring

Wiring diagram for LC800-RF and LC801-RF models with wireless siren.

INSTALLATION WARNINGS

General Installation Precautions

Important safety and installation precautions to prevent damage or malfunction.

ELECTRICAL CONNECTIONS

Input Functions

Configuration and function of various input wires for sensors and signals.

Output Functions

Functionality and programming of various output signals for alarms and indicators.

ULTRASOUND SENSOR ADJUSTMENT

Mounting and Sensitivity Settings

Guidance on mounting, orientation, and adjustment of the ultrasound sensor.

CAN NETWORK SYSTEM MODES

CAN-BUS Line Management

Details system arming/disarming and alarm cause management via CAN-BUS.

Vehicle Code Programming

Procedure for configuring the system with specific vehicle codes via button or PC.

ANALOGICAL SIGNAL CONNECTIONS

Door Lock Motor Unit Management

Connecting and managing system via analog signals from door lock motor unit.

DIRECTION INDICATOR CONNECTIONS

Arming;Disarming via Indicators

Schematic for arming/disarming system using vehicle direction indicators.

LEARNING MODES

Direction Indication & Engine Power Learning

Learning mode for direction indicators and engine power signals.

ANALOG CONNECTIONS AND LEARNING

Analog Signal Learning Procedure

Procedure for learning analog signals for arming/disarming.

ALARM INPUT FUNCTIONING MODES

Input Signal Types and Functions

Describes functioning modes of various alarm inputs like doors, bonnet, trunk, and sensors.

Inhibition and Exclusion Features

Details inhibition, exclusion, and bi-volumetric functions for alarm inputs.

ALARM OUTPUT OPERATING MODES

Output Signal Types

Describes various operating modes of alarm outputs, including positive and negative signals.

Programmable Output Settings

Details programmable settings for outputs like hazard command, timed signals, and vehicle closure.

OTHER ALARM OPERATION MODES

Passive Arming and Dashboard Switching

Explains passive arming, dashboard switching, and engine block relay default settings.

ELECTRONIC KEY FUNCTIONS

Exclusion of Acoustic Signals

Procedure to disable arming/disarming acoustic signals using the electronic key.

ELECTRONIC KEY MANAGEMENT

Key Learning and Deletion Procedures

Steps for learning new keys and deleting all learned devices.

COMPUTER PROGRAMMING AND UPDATES

Car Software Update Procedure

Guide for updating vehicle software via PC connection using the programmer tool.

VEHICLE ARMING DESCRIPTION

Arming Phases and Signals

Details pre-alarm time, system armed status, and neutral time with alarm cycles.

SENSOR EXCLUSION FUNCTIONS

Exclusion Methods

Methods to exclude sensors using remote control, electronic key, or LED button.

SYSTEM DISARMING AND ALARM MEMORY

Alarm Cause Identification

How to identify the cause of the last alarm using LED indication.

EMERGENCY AND GARAGE MODES

Disarming Procedures

Procedures for emergency disarming and total garage mode disarming via electronic key.

EMERGENCY DISARMING VIA BUTTON;LED

PIN Code Entry Procedure

Step-by-step guide to disarm the system using the PIN code via the LED button.

NEW EMERGENCY PIN-CODE PROGRAMMING

PIN Code Customization Process

Procedure to customize the emergency PIN code.

PIN-CODE STORAGE

Storing the New PIN Code

Instructions for storing the newly programmed PIN code.

PROBLEM SOLVING

Troubleshooting Common Issues

Guide to diagnose and resolve common system activation and operation problems.

TECHNICAL DATA

Product Homologation and Notes

Information regarding European directives, homologation, and manufacturer notes.

INSTALLATION CERTIFICATE

Installer Certification Form

Template for professional installers to certify system installation according to instructions.

Related product manuals