30
Technical data
Function Range
Accuracy
% of measured value (rdg)
+ least signicant digits
DC voltage
400.0 mV ± (1,0% rdg ± 8 digits)
4.000 V
40.00 V
400.0 V
± (1,0% rdg ± 3 digits)
600 V ± (1,2% rdg ± 3 digits)
AC voltage
50-60 Hz
True rms
4.000 V
40.00 V
400.0 V
± (1,0% rdg ± 5 digits)
600 V ± (1,2% rdg ± 5 digits)
DC current
400.0 μA ± (1,0% rdg ± 3 digits)
4.000 μA
40.00 mA
± (1,5% rdg ± 3 digits)
10A ± (2,5% rdg ± 5 digits)
AC current
50-60 Hz
True rms
400.0 μA ± (2,0% rdg ± 5 digits)
4.000 μA
40.00 mA
± (2,5% rdg ± 5 digits)
10A ± (3,0% rdg ± 7 digits)
Resistance
400.0 Ω ± (1,0% rdg ± 4 digits)
± (1,5% rdg ± 2 digits)
40.00 MΩ ± (3,5% rdg ± 3 digits)
Capacitance
40.00 nF ± (5,0% rdg ± 35 digits)
400.0 nF
± (3,0% rdg ± 5 digits)4.000 µF
40.00 µF
400.0 µF ± (4,0% rdg ± 5 digits)
4000 µF ± (5,0% rdg ± 5 digits)
Frequency
9.999 Hz
± (1,0% rdg ± 5 digits)
99.99 Hz
999.9 Hz
9.999 kHz
Duty cycle
1%…99% ± (1,2% rdg ± 2 digits)
Pulse width: 100 μs ... 100 ms
Frequency: 5 Hz ...100 kHz
EN