Function Maximum limit values
Max. input voltage between the
respective input terminals and earth:
V AC, V DC 10 MΩ input impedance
V AC, V DC, frequency, duty cycle 600 V rms
Resistance, continuity, capacitance,
diode test
250 V rms
Max. input current and fuse protection in current measurement:
10A AC/DC
Fast-acting fuse 10 A / 600 V
rms (on-time max. 30 sec. every
15 min.)
μA AC/DC, mA AC/DC
Fast-acting fuse
500 mA / 600 V rms
Maximum limit values
AUTO OFF function
In order to preserve the batteries, the meter switches off auto-
matically if it is left idle for 15 minutes. To protect the function
the Mode button is held pressed during switch-on.
Insertion of batteries
1
Attaching the test prods
2
To avoid the risk of injury, the test
prods must always be kept in the
holder at the rear of the device with
the protective caps tted when not
in use and during transportation.