Integral Process Thermostats and High-Temperature Thermostats
Operation manual
IN 130 T, IN 230 T, IN 230 TW, IN 530 T, IN 530 TW, IN 1030 T, IN 1330 TW, IN 1830 TW, IN 150 XT,
IN 250 XTW, IN 280 XT, IN 280 XTW, IN 550 XT, IN 550 XTW, IN 590 XTW, IN 750 XT, IN 950 XTW, IN 1590 XTW,
IN 1850 XTW, IN 2560 XTW, IN 2050 PW, IN 2560 PW, IN 4 XTW, IN 8 XTW
V6R9
Read this manual prior to performing any task!

Table of Contents

Questions and Answers

  • B
    Brett ReynoldsSep 10, 2025
    Why is degassing functioning poorly on my Lauda Thermostat?
    • M
      Mrs. Elizabeth MartinSep 10, 2025
      Degassing on your Lauda Thermostat might function poorly if pressure control is active, so switch it off. A pump level that is too high can also cause this, so select a lower pump level. Reduce the heating output, as it may be too high. If the cooling unit is active, switch it off. If the heat transfer liquid is heavily contaminated, change it. Ensure the filler nozzle is not closed by removing the tank lid and placing it loosely on the filler nozzle. If applicable, connect the inert gas blanket, with compressed air for pure degassing if necessary.
  • J
    Joseph HansenSep 12, 2025
    What does 'Pump blocked' mean on Lauda Thermostat display?
    • A
      Alexandra Hall MDSep 12, 2025
      The 'Pump blocked' message on your Lauda Thermostat display indicates a pump motor monitoring issue, such as overload or blockage. The viscosity of the heat transfer liquid may be too high; consider changing to another heat transfer liquid or increasing the set temperature.
  • C
    Carlos LaneSep 14, 2025
    What does 'Evaporator frozen' mean on Lauda Thermostat display?
    • M
      Monica MaynardSep 14, 2025
      The 'Evaporator frozen' message on your Lauda Thermostat display indicates that the evaporator is frozen. Increase the pump level. Open the manual bypass in the constant temperature equipment. Increase the flow rate through the application.
  • D
    dominguezjonathanSep 16, 2025
    What does 'Low level (pump)' mean on Lauda Thermostat display?
    • D
      David FoxSep 16, 2025
      The 'Low level (pump)' message on your Lauda Thermostat display indicates that the pump motor is idling. Check whether the float in the expansion vessel is blocked by a foreign object.

Summary

Safety

Safety information

Covers essential safety precautions and general guidelines for safe device operation.

Obligations of the operator

Details operator responsibilities and legal compliance requirements.

Safety fittings on the device

Covers safety fittings including overtemperature and low-level protection.

Overtemperature protection

Describes the overtemperature protection unit that prevents ignition of heat transfer liquid.

Low-level protection

Details the low-level protection unit preventing damage and ignition of heat transfer liquid.

Unpacking

Device description

Before starting up

Install device

Provides instructions and warnings for safely installing the device in its operational location.

LAUDA heat transfer liquids

Discusses LAUDA heat transfer liquids, their properties, and selection criteria.

Commissioning

Establishing a mains connection

Guides on connecting the device to the mains power supply, including safety notes.

Switching on the device for the first time

Details the procedure for initial device power-on and configuration sequence.

Setting heat transfer liquid

Guides on selecting and setting the appropriate heat transfer liquid for the device.

Operation

General warning

Provides a compilation of general warnings related to operating the device safely.

Setting Tmax

Guides on setting the maximum temperature (Tmax) and TmaxTank for safety and operational limits.

Safe Mode safety fittings

Details the Safe Mode function for emergency operation and fault handling.

Operation of a high-temperature thermostat

Operating a device with pressure overlay

Warnings, safety instructions and further information

Lists warnings, safety instructions, and intended/unintended use for pressure overlay devices.

Maintenance

Warning notes for maintenance

Compiles critical safety warnings related to performing maintenance on the device.

Checking the overtemperature protection

Explains how to check the overtemperature protection function for proper operation.

Checking the low-level protection

Details the procedure for checking the low-level protection function and its alarm.

Faults

Alarms, errors and warnings

Describes how alarms, errors, and warnings are displayed and handled on the device.

Troubleshooting

Provides a table of common faults, their causes, and possible remedies for process thermostats.

Decommissioning

Disposal

Lauda IN 530 T Specifications

General IconGeneral
Temperature Stability±0.01°C
Pump Pressure0.7 bar
Pump Capacity22 L/min
Power Supply50/60 Hz
Control TypeDigital
DisplayLCD