AT-200PC Commands
No Operation, Command code 0. This is a dummy command that produces no change in the
tuner.
Inductor Up, Command code 1. Increases inductance value by one unit.
Inductor down, Command code 2. Decreases inductance value by one unit.
Capacitor Up, Command code 3. Increases capacitance value by one unit.
Capacitor Down, Command code 4. Decreases capacitance value by one unit.
Memory Tune, Command code 5. Starts a memory tuning cycle. Automatically defaults to full
tune if no stored tuning parameters are available.
Full Tune, Command code 6. Starts a full tuning cycle even if stored tuning parameters are
available.
Set impedance range relay to High, Command code 8. Sets the Hi-Low Z range relay to the High
setting.
Set impedance range relay to Low, Command code 9. Sets the Hi-Low Z range relay to Low.
Select Antenna 1, Command code 10. Selects Antenna 1 on the internal antenna switch.
Select Antenna 2, Command code 11. Selects Antenna 2 on the internal antenna switch.
Update setting data, Command code 40. Requests the tuner to send updated data on the current
state of all tuning relays.
Request version number, Command code 41. Requests the tuner to send its product ID and
firmware version number
Arm memory clear, Command code 42. Enables clearing memory if the next command is Clear
Memory.
Clear memory, Command code 43. Clears EEPROM memory if the previous command was Arm
Memory Clear
Standby, Command code 44. Places the tuner in standby mode.
Activate, Command code 45. Takes tuner out of standby mode.
Store tuning parameters, Command Code 46. Stores the current tuning parameters for the present
frequency.