EasyManua.ls Logo

Leb Electronics CTR31: - D.7 Trimmers; D.8 Dip switches; D.9 Programming keys; D.10 Protection fuses

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
ENGLISH
LD3 – Opening limit switch led (yellow)
It signals the opening limit switch state. The led goes off when the gate has completely opened.
LD4 – Closing limit switch led (yellow)
It signals the closing limit switch state. The led goes off when the gate has completely closed.
LD1 – Programming led (red)
It is lit (together with the blinker) in the programming phase and during the gate’s motion.
7) Definitions of Trimmers
RV1 – Slow-down speed and power regulator
2 Functions: It defines the gate’s speed during the slow-down phase and it regulates the power supplied to the motor during the normal speed phase.
Clockwise rotation increases thrust or speed.
8) Definitions of Dip Switches (Selection logic of operation)
Dip switch 1
It enables the logic of operation “condominium”.
ON= Condominium OFF=Automatic or Step by Step (it depends on the position of Dip switch 2)
Dip switch 2
It enables the logic of operation “step-by-step” or “automatic”.
ON =Automatic OFF=Step by step
Dip switch 3
It disables the slow-down during the opening phase (during the closure phase the slow-down is always active).
ON=opening slow-down disabled OFF=opening slow-down enabled
Dip switch 4
It enables the closing start control or the pedestrian start control (input 13 of J4 terminal board)
ON=Pedestrian start enabled OFF=Closing start enabled
Dip switch 5 : NOT USED
9) Definitions of Programming Keys
P1 - Allows to insert/cancel the radio-command codes in the memory.
P2 - Allows to set the motor’s work time.
P3 - Allows to set the pause time.
10) Definitions of Protection Fuses
F1 – Mains power fuse (5A)
It disconnects the electronic unit from the power supply mains in case of short-circuit or electric current consumption anomalies.
F2 – Low voltage fuse (1A)
It protects the electronic unit in case of short circuits or over-currents on photo-cells or other accessory devices connected to the 24
Vac power supply.
Dip Switch
logic of
operation
1 2
off off Step by step
off ON Automatic
ON = Condominium

Table of Contents