LC Easyjet-16W/18S User Manual V13GZ.1
56
4. Bidirection Calibration
a) Click 4 pass Align, the printer will print some lines, as below:
The lines at “0” are the straightest ones, if not, users are suggested to make bid calibration
to ensure that the lines at “0” are the straightest ones.
For example, if you find the most straight lines are at number -4, then you need to use -4
plus the figure in , namely,-4+17=13, replace 17 with 13;
If you find the most straight lines are at number 4, then you need to use 4 plus the figure in
C , namely, 4+17=21, and then replace17 with 21.
After click Save, the 4 pass Align” is completed.
b) Click 6-12 pass Align, the printer will print some lines, as below:
The adjust method same as last step.
After click Save, the Bidirection Calibration is completed.
5. Step Calibration
Click Step Align and then click YES, the printer will print a frame, as below: