EasyManua.ls Logo

Leeson 174621 - Drive Ratings

Leeson 174621
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
174603
174604
174605
174606
174607
174608
174609
174610
174611
174612
174613
174614
174615
174616
174617
6
Technical data
2.2 Ratings
120VAC Doubler / 240VAC Models
Type Power
[Hp/kW]
Mains Output Current
Watts
Loss
Voltage
(1)
I
in
(120V) I
in
(240V) I
n
CLim
max
(2)
0.33 / 0.25
120 V Single-phase (1/N/PE)
(90 … 132 V)
OR
240 V Single-phase (2/PE)
(170 … 264 V)
6.8 3.4 1.7 200 24
0.5 / 0.37 9.2 4.6 2.4 200 32
1 / 0.75 16.6 8.3 4.2 200 52
240VAC Models
Type Power
[Hp/kW]
Mains Output Current
Watts
Loss
Voltage
(1)
I
in
1~ (2/PE) I
in
3~ (3/PE) I
n
CLim
max
(2)
0.33 / 0.25
240 V Single Phase (2/PE)
3.4 - 1.7 200 20
0.5 / 0.37
240 V Single-phase (2/PE)
OR
240 V Three-phase (3/PE)
(170 … 264 V)
5.1 2.9 2.4 200 27
1 / 0.75 8.8 5.0 4.2 200 41
1.5 / 1.1 12.0 6.9 6.0 200 64
2 / 1.5 13.3 8.1 7.0 200 75
3 / 2.2 17.1 10.8 9.6 200 103
1.5 / 1.1
240 V Three-phase (3/PE)
(170 V … 264 V)
- 6.9 6.0 200 64
2 / 1.5 - 8.1 7.0 200 75
3 / 2.2 - 10.8 9.6 200 103
5 / 4.0 - 18.6 16.5 200 154
7.5 / 5.5 - 26 23 200 225
10 / 7.5 - 33 29 200 274
(1) Frequency Range: 48 Hz … 62 Hz
(2) Current Limit (CLim) is a percentage of the output current, I
n
. CLim
max
is the maximum setting for P171.