MOSAIC NURSE CALL UNIT
EMERGENCY CALL
3 - Emergency call
BEEEP
BEEEP
In the room, the nurse activates
the emergency call by pressing the
bedhead corded push-button.
The door unit indicators and the
corridor over
door light flash quickly,
alternating red and white.
In the nurses' station, the indicator
flashes quickly, alternating red and white;
the audible signal beeps quickly.
Muting is not possible
from the nurses' station.
The nurse must go to the
patient's bedroom.
On entering the room, the
2nd nurse presses the door
unit push-button.
The door unit red indicator
and the corridor overdoor
light go out. The door unit
indicator and the corridor
overdoor light come on with a
steady white light.
In the nurses' station, the
red indicator goes out and
the white indicator returns to
steady state.
On leaving the room, the
nurse presses the door unit
push-button and clears the
call. All the indicators and
the overdoor light go out.
1 - Patient calls from room
AND/OR
2 - Nurse present in the room
1
4 5 6
7
2 3
NURSE PRESENT
3 - Another patient
The patient calls
room 2 by pressin
bedhead corded
button.
On entering room
2nd nurse press
doorunit push-butt
1 - Patient calls fro
2 - Nurse present
1
3