EasyManua.ls Logo

Leica Nova MS60 - Page 82

Leica Nova MS60
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MS60/TS60, Technical Data
82
Reflectors
There are no special prisms required for ATRplus or for PS.
Electronic Guide
Light EGL
Automatic Correc-
tions
The following automatic corrections are made:
Type Additive Constant [mm] ATRplus PS
Standard prism, GPR1 0.0 yes yes
Mini prism, GMP101 +17.5 yes yes
360° prism,
GRZ4 / GRZ122
+23.1 yes yes
360° Mini prism, GRZ101 +30.0 yes not recommended
Reflector tape S, M, L +34.4 yes no
Reflectorless +34.4 no no
Machine Automation
power prism, MPR122
For Machine
Control purposes
only!
+28.1 yes yes
Working range: 5 m to 150 m (15 ft to 500 ft)
Position accuracy: 5 cm at 100 m (1.97" at 330 ft)
• Line of sight error • Vertical index error
• Tilting axis error • Standing axis tilt
• Earth curvature • Refraction
• Circle eccentricity • ATRplus zero point error
• Compensator index error • Telescope camera zero point error