2. Setting up the instrument

3. Pointing to a reflector

3.1 With a T1010/1610

Details how to point the instrument using a specific reflector model for distance measurement.

3.2 With a TC1010/1610

Explains pointing procedures with a TC1010/1610 using a specific prism holder for distance measurement.

4. Getting started

4.1 Functional principles

Introduces the instrument's functional principles, including color-coded keys and menu structure.

4.4 Preparations for measurement

Details the necessary preparations before the first measurement, including unit settings and atmospheric data input.

5. Without data recording

5.1 Angle and distance measurement

Explains how to perform angle and distance measurements and set parameters without data recording.

5.4 Vertical-index error

Details the procedure for determining and storing the vertical-index error for improved accuracy.

5.5 Collimation error

Explains how to determine and store the collimation error for precise angle measurements.

6. With data recording

6.1 Plug-in REC module

Describes the REC module for data recording, its capacity, and its integration into the theodolite.

6.3 Recording a block of measurements

Explains how to define and record measurement blocks using specific masks in the theodolite.

7. Input of point number

9. Menu commands and functions

9.1 SET

Introduces the SET menu program for inputting station, target-point coordinates, and REM words.

9.3 REC

Covers REC commands for setting recording masks and defining masks for data storage.

9.4 CONF

Details configuration commands for managing system parameters and loading programs.

9.5 TEST

Describes test functions for interrogating instrument parameters and status, including battery and error checks.

11. Accessories

12. Inspecting and adjusting

12.4 Collimation error

Explains how the line of sight error is determined and incorporated into measurements.

17. Scale correction

17.1 Atmospheric correction

Explains how to compute atmospheric correction in ppm based on pressure and temperature.

10. Setting-out

10.1 Polar setting-out

Explains polar setting-out, computing differences between specified and measured length and height.

10.2 Orthogonal setting-out

Details orthogonal setting-out, showing transverse and longitudinal displacements and height differences.

13. Measuring to a reference line / building alignment