11
Extended guide
Use the power cord (L) to connect the machine to the electrical mains and turn
ON the machine by pressing the ON/OFF switch (6) (Pic 6.2). Once the display
shows the LELIT logo, follow the instructions that appear on the LCC (7): lift the
group lever (13), wait for the countdown (30 seconds) to nish and return the
group lever (13) in its original position. Wait until the bar is fully loaded and “OK”
appears on the display (less than 24 minutes).
The hydraulic circuit will need maximum 4 minutes from the 1st turn on to get
lled with water.
Now the hydraulic circuit is lled up. The machine will start heating the water to
reach the pre-set values. This operation requires maximum 24 minutes.
Note. It may happen that the LCC (7) shows to rell the water tank. Follow
the instruction to ll the hydraulic circuit correctly.
Once the water temperature has reached the pre-set values and the hydraulic
circuit is lled up, the LCC (7) will show the temperature inside the coffee boiler
and a coffee cup icon (Pic 6.3).
Attention. During the heating phase, a small quantity of water and steam will
drain in the tray (16). This is normal and conrms the machine correct functioning.
7. Connection to the water mains
The LELIT Bianca can also be connected to the water mains. The equipment
box contains the necessary components, but we suggest you contact a special-
ized technician for this operation and follow the instructions supplied with the
machine, our technical sheet #7900190 (inserted in the equipment box with the
pieces for the connection).
The water prole used with the coffee machine is a very important factor, and it
inuences the result in the cup and the machine performance in time. Below you
can see the prole that we suggest for a good and stable extraction:
Parameter Range
Chlorine (ppm Cl2) 0
pH 6,5 - 7,5
Total Hardness (ppm CaCO3) 0 - 110
Carbonate Hardness (ppm CaCO3) 40 - 75
Chloride (ppm Cl-) < 30
Sulphate (ppm SO4) < 50