EasyManua.ls Logo

LEMKEN Heliodor 8 - Maintenance Intervals; After Commissioning (Within 2 Hours); Daily Check; Weekly Check

LEMKEN Heliodor 8
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and repairs
89
15.3 Maintenance intervals
15.3.1 After commissioning (within 2 hours)
Check What to do?
Screw connections
Retighten all bolts and nuts on the device to the ap-
propriate torque. See section entitled “Tightening tor-
ques”.
15.3.2 Daily check
Check What to do?
Hydraulic hoses
Check hydraulic hoses for damage and leaks.
Replace damaged or defective hydraulic hoses im-
mediately.
The hydraulic hoses must be replaced 6 years after the
date of manufacture at the latest. Only used hydraulic
hoses approved by Lemken.
Safety equipment
Check that all safety equipment is functioning
properly. See "Safety equipment" section.
Soil processing tools
Check all soil processing tools for damage and wear.
Replace damaged or worn components.
15.3.3 Weekly check
Check What to do?
Screw connections
Tighten all screws and nuts on the implement to
the appropriate tightening torque.
If necessary, secure the screw connections with
screw locking devices.
See section entitled “Tightening torques”.

Table of Contents