Specications
SPECIFICATIONS
General
Data
Model No. All Regions 16ACX-024 16ACX-036 16ACX-048 16ACX-060
Nominal Tonnage 2345
1
Sound Rating Number (dB) 77 76 78 75
Connections
(sweat)
Liquid line (o.d.) - in. 3/8 3/83/8 3/8
Suction line (o.d.) - in. 3/4 7/87/8 1-1/8
Refrigerant
2
R-410A charge furnished 7 lbs. 2 oz.9 lbs. 0 oz.10 lbs. 6 oz.13 lbs. 2 oz.
Outdoor
Coil
Net face area - sq. ft. Outer coil 24.50 16.3321.00 29.09
Inner coil - - -15.76 20.2728.24
Tube diameter - in. and No. of rows 5/16 - 15/16 - 25/16 - 25/16 - 2
Fins per inch 26 22 22 22
Outdoor
Fan
Diameter - in. and No. of blades 22 - 322 - 322 - 326 - 3
Motor hp 1/6 1/41/4 1/4
Cfm 3260 3450 3800 4375
Rpm 825 825825 825
Watts 220 290305 270
Shipping Data - lbs. 1 pkg. 190 190235 285
ELECTRICAL DATA
Line voltage data - 60hz
5
230V-1ph
5
230V-1ph
5
230V-1ph
5
230V-1ph
3
Maximum overcurrent protection (amps) 20 30 40 50
4
Minimum circuit ampacity 15.6 20.8 29.2 35.7
Compressor Rated load amps 10.2 14.2 17 23.5
Locked rotor amps 55 78 109118
Power factor 0.98 0.95 0.97 0.95
Outdoor Fan
Motor
Full load amps 1.0 1.71.7 1.4
Locked Rotor amps 1.9 3.23.2 3.2
CONTROLS - ORDER SEPARATELY
iComfort
®
M30 Smart Wi-Fi Thermostat 15Z69
••••
Remote Outdoor Temperature Sensor X2658
••••
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Blower Relay Kit
(for constant torque gas furnaces)
85W66
••••
Compressor Crankcase Heater 93M04 ••FactoryFactory
Compressor Hard Start Kit - Required in
applications with less than 230V
63W22
10J42 ••
63W24
45F08
••••
Compressor Sound Cover 27W55 ••
27W56
••
47J27
••••
Freezestat 3/8 in. tubing 93G35
••••
5/8 in. tubing 50A93
••••
58M81
••••
Indoor Blower Speed Relay Kit 40K58
••••
6
Low Ambient Kit (Fan Cycling) 34M72
••••
Refrigerant
Line Sets
L15-41-20 L15-41-40
L15-41-30 L15-41-50
L15-65-30 L15-65-40
L15-65-50
••
Field Fabricate
94J45
••••
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Sound Rating Number in accordance with test conditions included in AHRI Standard 270.
2
additional refrigerant charge required.
3
HACR type breaker or fuse.
4
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Hard Start Kit is required in applications where the supply voltage is less than 230V.
6
Freezestat is recommended with Low Ambient Kit.