EasyManuals Logo

Lennox 16B27 User Manual

Lennox 16B27
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Page 4
OUTDOOR
AIR SENSOR
HEAT
1234
COOL
1234
DELAY
1234
ADJUST
NORM +
HUMIDIFICATION
SMART AUTO
EVENHEAT
1234
BLOWER
ONLY CFM
100
115
130
85
Y1−Y2
2−STAGE
COMPR
R−O
HEAT
PUMP
R− DS
DEHUM
OR
C
W1
W2
G
Y2
Y1
C
R
DH
H
L
O
DS
W3
FACTORY
JUMPER
FUSE3 AMP
XFMR 24V
24 VAC
COM
3
6
9
1
4
7
XFMR LINE
G
DEHUMIDIFICATION−
HARMONY LINK
(JUMPERS R to DS)
HEAT PUMP LINK
(JUMPERS R to O)
2−STAGE
COMPRESSOR LINK
(JUMPERS Y1 to Y2)
ON−BOARD LINK
OPTION SELECTION
1
CBA38MV, CBX32MV &
CBX40UHV
JUMPER & LINK GUIDE
−CUT ON−BOARD LINK (SOLDER TRACE) COMPLETELY
THROUGH BOTH LAYERS ON THE CONTROL BOARD
1
COOLING BLOWER RAMPING
DELAY
PROFILE #3
OFF−82%−100%−OFF
DELAY
PROFILE #2
HP: OFF−30sOFF−100%−100% OFF
DELAY PROFILE #1
OFF−100%−OFF
DELAY
PROFILE #4
OFF−50%−82%−100%−50%−OFF
*
(COOLING MODE UNLESS NOTED)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
*
HUMIDIFICATION MODE
SMART MODE
”H” ENABLED WHEN
HEAT ACTIVE
(HP or ELECT. HT)
AUTO MODE
”H” ENABLED WHEN
BLOWER ACTIVE
& NO CLG
OR DEHUM
HUMIDIFICATION MODE
24VAC OUTPUT ON ”H”
FOR HUMIDIFIER OR
ACCESSORY INTERLOCK
SMART
AUTO
SMART
AUTO
FACTORY DEFAULT SETTING
*
COOLING MODE
BLOWER SPEED
HIGH
SPEED
MEDIUM−LOW
SPEED
LOW
SPEED
1
2
3
4
MEDIUM−HIGH
SPEED
*
1
2
3
4
1
2
3
4
1
2
3
4
(COOLING & HP MODE)
STANDARD
HEAT MODE
(STAGED BY TSTAT)
STANDARD HEAT MODE
(DEFAULT)
85
110
115
130
HEATING MODE
BLOWER SPEED
*
(ELECTRIC HT MODE)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
LOW
SPEED
MEDIUM−LOW
SPEED
MEDIUM−HIGH
SPEED
HIGH
SPEED
NORM
+
NORM
+
NORM
+
BLOWER
ADJUST SELECTION
NORMAL
(+ 10%)
SETTING
(−10%)
SETTING
*
*
EVENHEATER
MODE
85
DEGREE TARGET
DISCHARGE
TEMPERATURE
100
DEGREE
TARGET
115
DEGREE
TARGET
130
DEGREE
TARGET
85
110
115
130
−ENABLED WITH OPTIONAL
DISCHARGE AIR SENSOR
85
110
115
130
85
110
115
130
85
110
115
130
PUSH
BUTTON
HIGH
SPEED
(100%)
MEDIUM−HIGH
SPEED
(70%)
LOW
SPEED
(28%)
*
MEDIUM−LOW
SPEED
(38%)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CONTINUOUS FAN
BLOWER SPEED
IMPORTANT: USE CARE WHEN CUTTING LINKS TO
PREVENT DAMAGE TO CONTROL.
2
5
8
P8
L1
L2
L2 L1
INDOOR
BLOWER
POWER
EARTH
INDOOR BLOWER
SIGNAL
45 6
12 3
A92
INTEGRATED
CONTROL
OUTDOOR UNIT
LINK
I +I
I +IRC
I +IRC
THERMOSTAT
HUMIDITROL
DH
DISCHARGE
AIR SENSOR
HARMONY
R−DS
DEHUM
or
NO HARMONY ZONING
OR NO
COMFORTSENSE 7000
W/ DS CONNECTION
DO NOT CUT
HARMONY ZONING
OR
C0MFORTSENSE 7000
W/ DS CONNECTION
CUT LINK
HARMONY
R−DS
DEHUM
or
HARMONY
1
A/C UNIT HEAT PUMP UNIT
R−0
HEAT
PUMP
R−0
HEAT
PUMP
1
DO NOT CUT
CUT LINK
2 STAGE
COMPR
1−STG COMPRESSOR
2−STG COMPRESSOR
Y1−Y2
1
DO NOT CUT
CUT LINK
*
*
*
2 STAGE
COMPR
Y1−Y2
AC: FF−100%−100%−OFF
SINGLE
CHARACTER
DISPLAY
(Non-Communicating)
Figure 3. Air Handler Conguration (Non-Communicating)

Other manuals for Lennox 16B27

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox 16B27 and is the answer not in the manual?

Lennox 16B27 Specifications

General IconGeneral
BrandLennox
Model16B27
CategoryHeat Pump
LanguageEnglish

Related product manuals