8
waiting
The snow flake icon indicates that the next mode of operation will be cooling.
The word waiting next to the icon indicate that system operation is waiting for the
completion of the 5-minute default compressor delay.
The blue flame icon is displayed when the system is cooling mode.
The schedule icon indicates that the system is transitioning to the next sched
uled temperature setting. This icon will only appear if smooth setback recovery is
enabled during installer setup. When enabled, the system will begin recovery up
to two hours before the programmed time to reach the programmed temperature
at the programmed event time. The system will recover 12°F per hour for gas/
electric heating and 6°F per hour for first-stage compressor-based cooling. When
smooth set back recovery is disabled, the control will start recovery at the pro
grammed time set in the schedule.