Page 4
Fuel Gas Code (ANSI-Z223.1/NFPA 54). The National
Fuel Gas Code is available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes
and other applicable local codes.
In order to ensure proper unit operation in non-direct vent
applications, combustion and ventilation air supply must
be provided according to the current National Fuel Gas
Code or CSA-B149 standard.
Installation Locations
7KLVIXUQDFHLV&6$,QWHUQDWLRQDOFHUWL¿HGIRULQVWDOODWLRQ
clearances to combustible material as listed on the unit
QDPHSODWHDQGLQWKHWDEOHLQ¿JXUH$FFHVVLELOLW\DQG
VHUYLFHFOHDUDQFHVPXVWWDNHSUHFHGHQFHRYHU¿UHSURWHF-
tion clearances.
NOTE - )RULQVWDOODWLRQRQFRPEXVWLEOHÀRRUVWKHIXUQDFH
VKDOO QRW EH LQVWDOOHG GLUHFWO\ RQ FDUSHWLQJ WLOH RU RWKHU
FRPEXVWLEOHPDWHULDORWKHUWKDQZRRGÀRRULQJ
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
ÀRRU7KH IXUQDFHPXVWEHORFDWHGRU SURWHFWHGWRDYRLG
physical damage by vehicles. When a furnace is installed
in a public garage, hangar, or other building that has a
KD]DUGRXVDWPRVSKHUHWKHIXUQDFHPXVWEHLQVWDOOHGDF-
cording to recommended good practice requirements and
current National Fuel Gas Code or CSA B149 standards.
NOTE - )XUQDFHPXVWEHDGMXVWHGWRREWDLQDWHPSHUDWXUH
ULVHZLWKLQWKHUDQJHVSHFL¿HGRQWKHXQLWQDPHSODWH)DLO-
XUHWRGRVRPD\FDXVHHUUDWLFOLPLWRSHUDWLRQDQGSUHPD-
WXUHKHDWH[FKDQJHUIDLOXUH
This EL196UHE furnace must be installed so that its elec-
trical components are protected from water.
Installed in Combination with a Cooling Coil
When this furnace is used with cooling coils (Figure 3),
it shall be installed in parallel with, or on the upstream
side of, cooling coils to avoid condensation in the heating
compartment.
:LWK D SDUDOOHO ÀRZ DUUDQJHPHQW D GDPSHU RU RWKHU
PHDQVWRFRQWUROWKHÀRZRIDLUPXVWDGHTXDWHO\SUHYHQW
chilled air from entering the furnace. If the damper is man-
ually operated, it must be equipped to prevent operation of
either the heating or the cooling unit, unless it is in the full
HEAT or COOL setting.
When installed, this furnace must be electrically grounded
according to local codes. In addition, in the United States,
installation must conform with the current National Elec-
tric Code, ANSI/NFPA No. 70. The National Electric Code
(ANSI/NFPA No. 70) is available from the following ad-
dress:
National Fire Protection Association
1 Battery March Park
Quincy, MA 02269
In Canada, all electrical wiring and grounding for the unit
must be installed according to the current regulations of
the Canadian Electrical Code Part I (CSA Standard C22.1)
and/or local codes.
Gas Unit
Heating Unit Installed Upstream of Cooling Unit
Gas Unit
Dampers
(open during heating operation only)
Dampers
(open during cooling operation only)
Heating Unit Installed Parallell to Air Handler Unit
Air Handler Unit
Evaporator
Figure 3
NOTE - 7KLVIXUQDFHLVGHVLJQHGIRUDPLQLPXPFRQWLQX-
RXVUHWXUQDLUWHPSHUDWXUHRI)&RUDQLQWHUPLWWHQW
RSHUDWLRQGRZQWR)&GU\EXOEIRUFDVHVZKHUHD
QLJKWVHWEDFNWKHUPRVWDWLVXVHG5HWXUQDLUWHPSHUDWXUH
PXVWQRWH[FHHG)&GU\EXOE
The EL196UHE furnace may be installed in alcoves, clos-
ets, attics, basements, garages, crawl spaces and utility
URRPVLQWKHXSÀRZRUKRUL]RQWDOSRVLWLRQ
7KLVIXUQDFHGHVLJQKDVQRWEHHQ&6$FHUWL¿HGIRULQVWDO-
lation in mobile homes, recreational vehicles, or outdoors.
Use of Furnace as Construction Heater
Units may be used for heating of buildings or structures
under construction, if the following conditions are met to
ensure proper operation:
DO NOT USE THE UNIT FOR CONSTRUCTION HEAT
UNLESS ALL OF THE FOLLOWING CRITERIA ARE
MET:
• )XUQDFHPXVWEHLQLWV¿QDOORFDWLRQ7KHYHQW V\VWHP
must be permanently installed per these installation in-
structions.
• Furnace must be installed as a two pipe system and
one hundred percent (100%) outdoor air must be pro-
vided for combustion air requirements during construc-
tion.
• A room thermostat must control the furnace. The use
RI¿[HGMXPSHUVWKDWZLOOSURYLGHFRQWLQXRXVKHDWLQJLV
prohibited.
• The input rate and temperature rise must be set per the
furnace rating plate.
• Supply and Return air ducts must be provided and
sealed to the furnace. Return air must be terminated
outside of the space where furnace is installed.