Page 1
2000 Lennox Industries Inc.
Dallas, Texas
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
INSTALLATION
INSTRUCTIONS
G24M Series
GAS FURNACE
SureLight Ignition System
504,197M
02/2000
Supersedes 503,981M
Table of Contents
G24M Unit Dimensions 2. . . . . . . . . . . . . . . . . . . . . .
G24M Parts Arrangement 3. . . . . . . . . . . . . . . . . . . .
G24M Gas Furnace 3. . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List 3. . . . . . . . . . . . . . . . . . . .
Requirements 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combustion, Dilution & Ventilation Air 5. . . . . . . . . .
Setting Equipment 8. . . . . . . . . . . . . . . . . . . . . . . . . .
Duct System 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Venting 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Piping 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Start-up 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Pressure Adjustment 25. . . . . . . . . . . . . . . . . . .
High Altitude Information 25. . . . . . . . . . . . . . . . . . . .
Other Unit Adjustments 25. . . . . . . . . . . . . . . . . . . . .
Service 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repair Parts List 28. . . . . . . . . . . . . . . . . . . . . . . . . . .
Ignition Control Board Diagnostic Codes 28. . . . . .
Troubleshooting 29. . . . . . . . . . . . . . . . . . . . . . . . . . .
G24M Start-up & Performance Check List 32. . . . .
WHAT TO DO IF YOU SMELL GAS:
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or death.
WARNING
Do not store or use gasoline or oth
er flammable vapors and liquids in
the vicinity of this or any other ap
pliance.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
Extinguish any open flames.
Litho USA
Question and Answer IconNeed help?

Do you have a question about the Lennox G24M3/4-100 and is the answer not in the manual?

Lennox G24M3/4-100 Specifications

General IconGeneral
BrandLennox
ModelG24M3/4-100
CategoryFurnace
LanguageEnglish

Summary

Combustion Air Requirements

Ventilation for Combustion and Dilution

Explains the need for proper air supply for combustion and dilution, addressing infiltration and tight construction.

Venting Requirements

Electrical Connections

Unit Start-Up Procedures

Operation and Adjustments

Service and Maintenance

Routine Service Checks

Covers essential service checks for electrical, blower, filters, flue, and burners at the start of the heating season.

Troubleshooting Heating

Heating Sequence Troubleshooting

Flowcharts and steps for diagnosing issues during the heating sequence of operation.

Heating Sequence Troubleshooting Continued

Further steps and logic for troubleshooting abnormal heating sequences and watchguard modes.

Troubleshooting Cooling

Cooling Sequence Troubleshooting

Flowcharts and steps for diagnosing issues during the cooling sequence of operation.

Start-up and Performance Check List

G24M Start-up Checklist

A comprehensive checklist for starting up the G24M furnace and verifying performance.