Crucial safety precautions including lock-out/tag-out, moving parts, and electrical hazards.
Details available economizer system options.
Details cooling capacity, airflow, power, EER, and IEER ratings.
Lists refrigerant type and charge amounts per circuit.
Information on blower motor output and drive kit numbers.
Specifies filter type, size, and electrical characteristics.
Details usage, derate, and input rates for gas heating.
Lists minimum and maximum CFM values for blower speeds.
Details electrical data for 13-ton high-efficiency units.
Details electrical data for 15-ton high-efficiency units.
Details electrical data for 17.5-ton high-efficiency units.
Details electrical data for 20-ton high-efficiency units.
Details electrical data for 25-ton standard-efficiency units.
Details electrical data for 15-ton ultra-high-efficiency units.
Details electrical data for 20-ton ultra-high-efficiency units.
Details electrical data for 25-ton ultra-high-efficiency units.
Controls and monitors the VFD A96.
Diagram showing compressor and switch details.
Details compressor types and quantities per model.
Explains high-pressure switches and their function.
Describes low ambient switches for operation at low temperatures.
Details freezestats to prevent evaporator coil icing.
Procedure to adjust motor pulley for desired CFM.
Details the UTEC ignition controls and LED codes.
Procedures for checking cooling system charge using approach method.
Illustrates the heat exchanger assembly and its function.
Warnings and procedures for charging aluminum coils.
Important procedure for charging the unit in standard cooling mode.
Table of normal operating pressures for cooling circuits.
Table of VAV normal operating pressures for cooling circuits.
Table of operating pressures for LGH180H CAV/Staged units.
Table of VAV operating pressures for LGH180H units.
Table of reheat operating pressures for LGH210H units.
Table of reheat operating pressures for LGH240H units.
Table of operating pressures for LGH300S units.
Charging curve for LGH/LCH156 CAV/Staged Circuit 1.
Charging curve for LGH/LCH156 CAV/Staged Circuit 3.
Reheat charging curve for LGH/LCH156 Circuit 2.
VAV charging curve for LGH/LCH156 Circuit 1.
VAV charging curve for LGH/LCH156 Circuit 3.
Charging curves for LGH/LCH180 CAV/Staged Circuit 1.
Charging curves for LGH/LCH180 CAV/Staged Circuit 3.
Reheat charging curves for LGH/LCH180 Circuit 1.
Reheat charging curves for LGH/LCH180 Circuit 3.
VAV charging curves for LGH/LCH180 Circuit 2.
Table of normal operating pressures for reheat circuits.
Table of operating pressures for LGH180H Reheat units.
Table of operating pressures for LGH210H units.
Table of operating pressures for LGH240H CAV/Staged units.
Table of VAV operating pressures for LGH240H units.
Table of reheat operating pressures for LGH300S units.
Charging curve for LGH/LCH156 CAV/Staged Circuit 2.
Reheat charging curve for LGH/LCH156 Circuit 1.
Reheat charging curve for LGH/LCH156 Circuit 3.
VAV charging curve for LGH/LCH156 Circuit 2.
Charging curves for LGH/LCH180 CAV/Staged Circuit 2.
Reheat charging curves for LGH/LCH180 Circuit 2.
VAV charging curves for LGH/LCH180 Circuit 1.
VAV charging curves for LGH/LCH180 Circuit 3.
Compares liquid temperature to outdoor ambient for charge verification.
Procedure for starting the unit in cooling mode.
Critical safety warnings before lighting the appliance.
Step-by-step guide for placing the furnace into operation.
Instructions for performing a safety or emergency shutdown.
Procedures for checking gas piping and supply pressure.
Sequence for first stage cooling operation.
Sequence for second stage cooling operation.
Sequence for first stage cooling operation.
Sequence for second stage cooling operation.