EasyManua.ls Logo

Lennox SL280UHNV - Unit Dimensions

Lennox SL280UHNV
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2
Unit Dimensions - inches (mm)
Model No.
A B C D
in. mm in mm in mm in mm
SL280UH060NV36A 14-1/2 368 13-3/8 340 13 330 4-3/4 121
SL280UH080NV48B 17-1/2 446 16-3/8 416 16 406 6-1/4 159
SL280UH080NV60C
21 533 19-7/8 504 19-1/2 495 8 203
SL280UH100NV60C
AIR FLOW
23
(584)
(19)
3/4
(19)
1
Bottom Return
Air Opening
³ GAS PIPING INLET
“B” and “C” Width Cabinets
(Either Side)
Side Return
Air Opening
(Either Side)
1
Bottom Return
Air Opening
FLUE OUTLET
(Top)
ELECTRICAL INLET
(Either Side)
SUPPLY AIR
OPENING
FRONT VIEW SIDE VIEW
TOP VIEW
A
B
9/16 (14)
C
D
3/4
27-3/4
(705)
19-7/16
(494)
23-1/2
(597)
1-1/2
(38)
9-1/8 (232) Right
8-5/8 (219) Left
5-3/8 (137) Right
2-3/16 (56) Left
33
(838)
3-1/8 (79)
1-15/16 (49)
14
(356)
9/16
(14)
2
OPTIONAL
EXTERNAL
SIDE RETURN
AIR FILTER KIT
(Either Side)
16
(406)
14-3/4
(375)
2
OPTIONAL
EXTERNAL
SIDE RETURN
AIR FILTER KIT
(Either Side)
2
Optional External Side Return Air Filter Kit is not for use
with the optional Return Air Base.
3
NOTE - Gas entry is only available on the left side of the
cabinet for “A” width cabinet models.
1
5/8
(16)
1
3-1/4
(83)
23-3/4
(603)
25
(635)
1-1/2 (38)
Front Panel
NOTE - 60C size units that require air volumes over
1800 cfm must have one of the following:
1. Single side return air and Optional Return Air Base
with transition that must accommodate required
20 x 25 x 1 inch (508 x 635 x 25 mm) air filter to
maintain proper velocity.
2. Bottom return air.
3. Return air from both sides.
4. Bottom and one side return air.
See Blower Performance Tables for additional information.
³ GAS PIPING INLET
“A” Width Cabinet
(Left Side Only)

Other manuals for Lennox SL280UHNV