XC21 - 2 to 5 Ton Air Conditioner / Page 22
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC21-036-230 TXV 35,800 18.70 13.20 CH23-51 SLP98UH070V36B 4261204
XC21-036-230 TXV 35,600 19.00 13.20 CH23-51 SLP98UH090V36C 4261205
XC21-036-230 TXV 36,000 19.00 13.50 CH23-51 SLP98UH090V48C 4261206
XC21-036-230 TXV 35,600 16.20 12.20 CH23-51 4261066
XC21-036-230 TXV 35,000 18.00 12.70 CH33-36 G61MPV-36B-045 4261151
XC21-036-230 TXV 35,000 18.00 12.70 CH33-36 G61MPV-36B-070 4261152
XC21-036-230 TXV 35,000 18.00 12.70 CH33-36 G61MPV-36B-071 4261269
XC21-036-230 TXV 35,600 18.50 13.20 CH33-36 G61MPV-36C-090 4261153
XC21-036-230 TXV 35,200 18.50 13.20 CH33-36 SL280UH090V36B 4261149
XC21-036-230 TXV 35,400 18.20 13.00 CH33-36 SL280UH090V48B 4261150
XC21-036-230 TXV 35,400 18.20 13.00 CH33-36 SL280UH090XV48B 4261236
XC21-036-230 TXV 35,000 18.20 12.70 CH33-36 SLP98UH070V36B 4261207
XC21-036-230 TXV 35,400 18.70 13.20 CH33-36 SLP98UH090V36C 4261211
XC21-036-230 TXV 35,800 18.50 13.20 CH33-36 SLP98UH090V48C 4261212
XC21-036-230 TXV 35,000 16.20 12.00 CH33-36B 4261067
XC21-036-230 TXV 35,400 16.20 12.00 CH33-36C 4261068
XC21-036-230 TXV 36,000 18.20 12.70 CH33-42 G61MPV-36B-045 4261156
XC21-036-230 TXV 36,000 18.20 12.70 CH33-42 G61MPV-36B-070 4261157
XC21-036-230 TXV 36,000 18.20 12.70 CH33-42 G61MPV-36B-071 4261270
XC21-036-230 TXV 36,000 18.50 13.00 CH33-42 G61MPV-36C-090 4261158
XC21-036-230 TXV 36,200 18.70 13.20 CH33-42 SL280UH090V36B 4261154
XC21-036-230 TXV 36,400 18.70 13.20 CH33-42 SL280UH090V48B 4261155
XC21-036-230 TXV 36,400 18.70 13.20 CH33-42 SL280UH090XV48B 4261237
XC21-036-230 TXV 36,000 18.50 13.00 CH33-42 SLP98UH070V36B 4261213
XC21-036-230 TXV 36,000 18.70 13.20 CH33-42 SLP98UH090V36C 4261214
XC21-036-230 TXV 36,200 18.50 13.20 CH33-42 SLP98UH090V48C 4261215
XC21-036-230 TXV 35,800 16.50 12.20 CH33-42 4261069
XC21-036-230 TXV 37,200 18.70 13.20 CH33-43 G61MPV-36B-045 4261084
XC21-036-230 TXV 37,400 19.00 13.20 CH33-43 G61MPV-36B-070 4261085
XC21-036-230 TXV 37,400 19.00 13.20 CH33-43 G61MPV-36B-071 4261271
XC21-036-230 TXV 37,000 19.20 13.50 CH33-43 G61MPV-36C-090 4261086
XC21-036-230 TXV 37,400 19.20 13.70 CH33-43 SL280UH090V36B 4261159
XC21-036-230 TXV 37,600 19.20 13.50 CH33-43 SL280UH090V48B 4261160
XC21-036-230 TXV 37,600 19.20 13.50 CH33-43 SL280UH090XV48B 4261238
XC21-036-230 TXV 37,400 19.00 13.50 CH33-43 SLP98UH070V36B 4261216
XC21-036-230 TXV 36,800 19.20 13.50 CH33-43 SLP98UH090V36C 4261217
XC21-036-230 TXV 37,000 19.20 13.70 CH33-43 SLP98UH090V48C 4261218
XC21-036-230 TXV 37,800 19.50 13.50 CH33-43 SLP98UH090V60C 4261261
XC21-036-230 TXV 37,600 19.50 13.70 CH33-43 SLP98UH110V60C 4261262
XC21-036-230 TXV 37,200 17.00 12.70 CH33-43B 4261070
XC21-036-230 TXV 36,600 16.70 12.50 CH33-43C 4261071
XC21-036-230 TXV 36,400 18.50 13.00 CH33-44/48 G61MPV-36B-045 4261161
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.