EasyManua.ls Logo

Lenovo ThinkSystem DE2000H 7Y71 - Step 1: Prepare to Replace Controller (Duplex)

Lenovo ThinkSystem DE2000H 7Y71
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.
Back up the storage array’s configuration database using ThinkSystem System Manager..
If a problem occurs when you remove a controller, you can use the saved file to restore your
configuration. The system will save the current state of the RAID configuration database, which
includes all data for volume groups and disk pools on the controller.
From ThinkSystem System Manager:
a.
Select Support › Support Center › Diagnostics.
b.
Select Collect Configuration Data.
c.
Click Collect.
Ê The file is saved in the Downloads folder for your browser with
the name,
*configurationData-<arrayName>-<dateTime>.7z*.
Alternatively, you can back up the configuration database by using the following CLI
command:
a.
Download SMcli from ThinkSystem System Manager and set up SMcli command
execution environment.
b.
Execute the following SMcli command:`save storageArray dbmDatabase
sourceLocation=onboard contentType=all file="filename";`
In this command, filename is the file path to which you want to save the database.
Enclose the file name in backslash following double quotation marks (\"). For example:
file="C:\Program Files\CLI\logs\dbmdata.zip"
This command does not automatically append a file extension to the saved file. You
must specify a file extension when entering the file name.
Notes:
Under PowerShell, enclose the file name following two quotation marks(""), for
example,
file=\""data.zip\"".
Execution environment requires setting JAVA_HOME environment variable, and
JRE8 or later.
See Command Line Interface (CLI) Reference and follow the complete command
syntax for this operation
6.
Collect support data for your storage array using ThinkSystem System Manager.
a.
Select Support › Support Center › Diagnostics.
b.
Select Collect Support Data.
c.
Click Collect. The file is saved in the Downloads folder for your browser with the name,
support-data.7z.
7.
If the controller is not already offline, take it offline now using either ThinkSystem System
Manager or the SMcli tool.