EasyManua.ls Logo

Lenze AC Tech SF210 - User Manual

Default Icon
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(217) 352-9330 | sales@artisantg.com | artisantg.com
-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your
definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
Critical
and
expedited
services
Leasing
/
Rentals/
Demos
In
stock/
Ready-to-ship
!TAR-certified
secure
asset
solutions
Expert
team
I
Trust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Lenze / AC Tech SF2200 at our website: Click HERE

Questions and Answers

  • Z
    Zachary JohnsonAug 17, 2025
    Why does my Lenze AC Tech SF210 show a Current Overload Fault?
    • T
      thomassmithAug 17, 2025
      A Current Overload Fault in your Lenze AC Tech Controller indicates that the VFD is undersized for the application or there is a mechanical problem with the driven equipment.
  • W
    waltonsarahAug 20, 2025
    What causes an Output Transistor Fault in Lenze AC Tech SF210 Controller?
    • D
      Daniel MartinAug 20, 2025
      An Output Transistor Fault in your Lenze AC Tech Controller can be triggered by a phase-to-phase or phase-to-ground short circuit on the output, a failed output transistor, boost settings that are too high, or an acceleration rate that is too fast.
  • R
    Richard CameronAug 22, 2025
    What causes a Low DC Bus Voltage Fault in Lenze AC Tech SF210?
    • G
      Gary PenaAug 22, 2025
      A Low DC Bus Voltage Fault in your Lenze AC Tech Controller is caused by line voltage that is too low.
  • R
    ricardo90Aug 26, 2025
    What to do if Lenze AC Tech SF210 Controller displays a Control Fault?
    • A
      Aaron RobersonAug 26, 2025
      If your Lenze AC Tech Controller displays a Control Fault, it may be due to a blank EPM or an EPM with corrupted data. Perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • Y
    Yolanda MclaughlinAug 28, 2025
    How to resolve Incompatibility Fault on Lenze AC Tech Controller?
    • G
      gfieldsAug 28, 2025
      An Incompatibility Fault on your Lenze AC Tech Controller indicates that an EPM with an incompatible parameter version has been installed. You can either exchange the EPM or perform a factory reset (Parameter 48) to change the parameter version of the EPM to match the parameter version of the drive.
  • R
    Richard ThompsonAug 30, 2025
    What does Single-phase Fault mean on Lenze AC Tech Controller?
    • E
      Elizabeth GuerreroAug 31, 2025
      A Single-phase Fault on your Lenze AC Tech Controller means that single-phase input power has been applied to a three-phase drive.
  • L
    Lisa LawsonSep 2, 2025
    Why does my Lenze AC Tech Controller show a Start Fault?
    • X
      xprattSep 3, 2025
      A Start Fault on your Lenze AC Tech Controller occurs when a start command was present when the drive was powered up. You must wait 2 seconds after power-up to apply the Start command if START METHOD is set to NORMAL.
  • L
    lanechristineSep 5, 2025
    What does External Fault mean on Lenze AC Tech SF210?
    • J
      jchapmanSep 5, 2025
      An External Fault occurs on your Lenze AC Tech Controller when TB-13A and/or TB-13C is set as an External Fault input and TB-13A and/or TB-13C is open with respect to TB-2. Refer to Parameter 10 or 12.
  • C
    Christopher GuerraSep 8, 2025
    What causes a Data Fault in Lenze AC Tech SF210?
    • H
      henrycherylSep 8, 2025
      A Data Fault in your Lenze AC Tech Controller indicates that user data and OEM defaults in the EPM are corrupted.
  • E
    Edward NormanSep 12, 2025
    What does Serial Fault mean on Lenze AC Tech SF210?
    • D
      Devon SmithSep 12, 2025
      A Serial Fault indicates that the watchdog timer has timed out, meaning the serial link has been lost on your Lenze AC Tech Controller.

Summary

SCF Sub-Micro Drive Overview

Safety Information and Icons

Defines signal words and icons used to convey safety information and warnings.

General Information and Safety

General Safety Precautions

Safety precautions for electrically live parts, hot surfaces, and potential hazards.

Electrical Connection Safety

Observe national safety regulations and EMC compliance for electrical installations.

Model and Specifications

SCF Specifications

Lists environmental, electrical, and performance specifications for the SCF drive.

SCF Ratings

Provides rating tables for motors, input/output current, and heat loss.

Installation Procedures

Environmental Conditions for Installation

Drives must not be installed in adverse environmental conditions.

Input AC Power Requirements

Safety and programming notes for AC power input.

Input Fusing and Disconnect Requirements

Requirements for circuit breakers, fuses, and disconnect switches.

Power Wiring

Power Wiring Safety

Capacitors retain charge; wait before servicing power wiring.

Wiring for Single and Three Phase Input

Instructions for single/three-phase inputs and motor output wiring.

SCF Power Wiring Diagrams

Power Wiring Diagrams

Diagrams for three-phase and single-phase power wiring connections.

Power Wiring Safety Notes

Do not connect AC power to output/DC bus terminals; wire/ground as per codes.

Speed Reference Selection

Jog Mode Operation

Programming TB-13B for Jog Forward/Reverse; safety warning.

Control Wiring Diagrams

Start;Stop Control Wiring

Alternate Start;Stop Control

Three-Wire Start;Stop Control

Speed Pot and Preset Speed Control

Initial Power Up and Motor Rotation

Power Up Safety Warnings

Electrical shock hazard; wait before servicing power connections.

Initial Motor Rotation Check

Procedure to verify motor rotation after initial power up.

Programming the SCF Drive

Programming Methods

Describes programming using buttons, EPM, or serial link.

Electronic Programming Module (EPM)

EPM Installation Warning

Do not remove EPM while power is applied; drive needs EPM to operate.

Parameter Menu

Parameter Menu Overview

Lists parameters, their range of adjustment, and factory defaults.

Parameter Descriptions (Part 1)

Details parameters for voltage, frequency, start/stop methods.

Parameter Descriptions (Part 2)

Details parameters for speed source, outputs, and function select.

Parameter Descriptions (Part 3)

Details parameters for analog outputs and function selects.

Parameter Details

Start Method Parameters

Explains different drive start methods (Normal, Power Up, DC Brake, Flying Restart).

Stop Method Parameters

Explains different drive stop methods (Coast, DC Brake, Ramp).

Terminal Function Selection

Drive Configuration Parameters

Acceleration Time

Sets the time to accelerate from 0 Hz to BASE FREQUENCY.

Motor and Speed Control Parameters

Deceleration Time

Sets the time to decelerate from BASE FREQUENCY to 0 Hz.

Motor Overload Protection

Sets adjustable thermal overload protection for the motor.

Base Frequency

Sets output frequency at which drive outputs full voltage to motor.

Advanced Drive Features

Parameter Management and Status

Program Selection (User;OEM;Reset)

Selects operation mode (User/OEM) or resets parameters to defaults.

Troubleshooting Faults

Troubleshooting Guide

Accessing parameters 50-60 for troubleshooting without password.

Fault Messages and Causes

Lists fault conditions, possible causes, and clearing procedures.

PI Setpoint Control Option

PI Control Overview

Describes the PI Setpoint Control software option and its parameters.

PI Parameter Descriptions (Part 1)

Details PI-specific parameters like TB-13 function select and PI MODE.

PI Parameter Descriptions (Part 2)

Details PI parameters like MIN/MAX FEEDBACK and gain settings.

PI Parameter Descriptions (Part 3)

Details PI parameters like PROPORTIONAL GAIN, INTEGRAL GAIN, PI ACCEL/DECEL.

PI Parameter Descriptions (Part 4)

Details PI parameters like MIN/MAX ALARM and feedback monitoring.

PI Control Wiring Examples

Tuning the PI Control

PI Control Tuning Procedures

Procedures for tuning PI control using Proportional and Integral Gain.

Lenze AC Tech SF210 Specifications

General IconGeneral
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Input Frequency50/60 Hz
Enclosure TypeIP20
Operating Temperature0-40°C (32-104°F)
Storage Temperature-20°C to +65°C
Humidity5-95% (non-condensing)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit