Technical Data
UOMu_^MVMO 3-3
150 % overload 8204820382028201Type
EVF8204-EEVF8203-EEVF8202-EEVF8201-EOrder no.
Variant ”reduced assembly
depth”
8202-V002TypeVariant ”reduced assembly
depth”
EVF8202-E- V002Order no.
Power derating [%/K]
[%/m]
40 °C<T
amb
<50°C: 2,5%/K
1000 m a.m.s.l.
< h ≤ 4000 m a.m.s.l.: 5%/1000 m
Field
Resolution Absolute 0.05 Hz
frequency
Digital setpoint
selection
Accuracy 0.05 Hz
Analog setpoint
Linearity 0.5 % (max. selected signal level, 5V or 10V)
selection
Temperature
sensitivity
0 ¼ 40 °C: +0.4 %
Offset 0.3 %
Weight m[kg] 1.0 1.3
Variant 1.0
2.2 2.2
1)
This power can be additionally obtained when operating a matching motor
2)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with 75% I
Nrated
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
4)
Observe the N-conduction load when having a symmetrical mains distribution!
(See electrical installation)
* Chopper frequency of the inverter
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com