Configuration
7-10 UOMu_^MVMO
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoSelectionLenze
Name
C144
¿
Chopper-frequency
reduction
821X/822X/824
X
-1- -0- No chopper-frequency reduction
-1- Automatic chopper-frequency lowering
when
J
max
-10°C
C161* Current fault Only display
C162* Last fault Only display
C163* Last but one
fault
Only display
C164* Last but two
fault
Only display
C170
¿
TRIP-reset
selection
-0- TRIP-reset by pressing the STP key or
LOW s ignal at ctrl. enable
-1- Auto-TRIP-Reset
C171 Delay for
Auto-TRIP-Reset
0 0{1s} 60
C178* Operating time Only display
C179* Mains switch-on
time
Only display
C377 Gain Zk-voltage
detection
822X/824X
Should only
be changed
by the Lenze
Service!
C500*
Display factor
application
datum
numerator
821X/822X/824
X
2000 1 {1} 25000
C501*
Display factor
for process
variable
denominator
821X/822X/824
X
10 1 {1} 25000