Troubleshooting and fault elimination
System error messages
General error messages
4

39
EDKVF93−05 EN 2.0
RemedyCauseErrorError number
x = 0: TRIP
x = 1: Message
x = 2: Warning
Display
Pin X9/8 is not assigned Assign pin X9/8 with 5 V or switch off
monitoring (C0587 = 3)
Sd5 x085 Encoder at X6/1,
X6/2 is defective
Current at X6/1, X6/2 < 2 mA l Check cable for wire breakage
l Check encoder
Sd6 x086 Sensor error at X8 KTY at X8 indicates undefined values l Check supply cable for firm
connection
l Switch off monitoring with
C0594 = 3 if necessary