6 Electrical installation
Cable cross-sections and screw-tightening torques
EDK82ZAFPC-010 DE/EN/FR 6.0
62
H2_LtgQuer+AnzMom-Steckerleiste_Federkraft
Cable cross-sections and screw-tightening torques
Field Values
Electrical connection Plug connector with double screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)
Stripping length 10 mm
Field Values
Electrical connection 2-pin plug connector with spring connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Stripping length 9 mm