System bus (CAN / CAN−AUX) configuration
Remote parameterisation (gateway function)
8
181
EDBCSXA064 EN 3.2
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0603 MONIT CE5 3
Fault response − gateway
function monitoring (CE5)
"Timeout" when remote
parameter setting (C0370) is
activated via interface X4 (CAN)
202
180
0 TRIP
2 Warning
3 Off
C2118 ParWriteChan
.
0
CAN object for L_ParRead and
L_ParWrite
(byComChannel = 10)
180
0 Unused PDO channel free for
reconfiguration
(CAN1...3_IN/CAN1...3_OUT)
1 Parameter data channel 2
C2470 ParWrite 0
CANaux channel used by
L_ParWrite/L_ParRead
(byComChannel = 11)
180
0 Unused PDO channel free for
reconfiguration
(CANaux1...3_IN/CANaux1...3_OUT)
1 Parameter data channel 2
C2485 MONIT CE15 3
Fault response − gate function
monitoring (CE15)
"Timeout" when remote
parameterisation (C0370) is
activated via interface X14
(CAN−AUX)
202
180
0 TRIP
2 Warning
3 Off

Table of Contents

Other manuals for Lenze ECSxK001 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSxK001 series and is the answer not in the manual?

Lenze ECSxK001 series Specifications

General IconGeneral
BrandLenze
ModelECSxK001 series
CategoryControl Unit
LanguageEnglish

Related product manuals