AIF interface (X1) configuration
Cycle time (XCAN1_OUT ... XCAN3_OUT)
9
189
EDBCSXA064 EN 3.2
Code for activating the transmission of event−controlled PDOs
Code Possible settings IMPORTANT
No. Designation Lenze/ap
pl.
Selection
C2364
0 Event−controlled PDO
transmission
(AIF interface X1)
0 Send PDOs when changing to
"Operational" state
1 Do not send PDOs
Code for enabling the second parameter data channel and the PDO channels
Code Possible settings IMPORTANT
No. Designation Lenze/ap
pl.
Selection
C2365 Enabling the second parameter
data channel and the PDO
channels
(AIF interface X1)
1 0 0 {1} 3 Enabling the second parameter
data channel
2 1 Enabling the first process data
channel
3 1 Enabling the second process data
channel
4 1 Enabling the third process data
channel
0 Deactivated
1 Activated
2 Reception activated
3 Transmission activated