EasyManuals Logo

Lenze ECSxK001 series User Manual

Lenze ECSxK001 series
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
Troubleshooting and fault elimination
Fault analysis
Fault analysis via LECOM status words (C0150/C0155)
12
240
EDBCSXA064 EN 3.2
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0155 Status word 2 0
Status word 2 (advanced status
word)
Display only
0 {1} 65535 Controller interprets information
as 16 bit (binary coded)
Bit 0 Active fault
Bit 1 M
max
reached
Bit 2 I
max
reached
Bit 3 Pulse inhibit(IMP)
Bit 4 Ready for operation (RDY)
Bit 5 Controller inhibit (CINH)
Bit 6 TRIP active
Bit 7 Initialisation
Bit 8 Motor direction of rotation (Cw/CCw)
Bit 9 Not assigned
Bit 10 Not assigned
Bit 11 Not assigned
Bit 12 Not assigned
Bit 13 Not assigned
Bit 14 Not assigned
Bit 15 Not assigned

Table of Contents

Other manuals for Lenze ECSxK001 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSxK001 series and is the answer not in the manual?

Lenze ECSxK001 series Specifications

General IconGeneral
BrandLenze
ModelECSxK001 series
CategoryControl Unit
LanguageEnglish

Related product manuals