Appendix
Index table
8
47
EDSMF2191IB EN 2.0
I−1C0F:
EPL CN: Frame error (CRC)
Index
0x1C0F
EPL name
DLL_CNCRCError_REC
Subcode Lenze Values Data type
1: CumulativeCnt_U32 U32
2: ThresholdCnt_U32 0 0, 1, 2, 3 ... U32
3: Threshold_U32 0 0, 1, 2, 3 ... U32
Access:
Subcode 3: rw , otherwise ro
The object indicates the number of frame checksum errors detected by the slave
(controlled node).
I−1C10:
EPL CN: Link interruptions
Index
0x1C10
EPL name
DLL_CNLossOfLinkCum_U32
Subcode Lenze Values Data type
−− U32
Access: ro
The object indicates the counter of the slave (controlled node) for Ethernet connection
interruptions.
Each event is counted. Every single event is followed by an error message. No threshold